Título: Automatic non-volcanic tremor detection in the Mexican subduction zone
Automatic non-volcanic tremor detection in the Mexican subduction zone
Autores: Husker, A.
Peyrat, S.
Shapiro, N.
Kostoglodov, V.
Fecha: 2010-01-25
Publicador: Revistas UNAM
Fuente:
Tipo:

Tema: Non-volcanic tremor; tremor detection; median filter
Descripción: An automatic non-volcanic tremor (NVT) detection algorithm is developed. NVT occurs in the 1 – 10 Hz frequency range, but high ambient noise dominates above 2 Hz at many of the MesoAmerican Seismic Experiment (MASE) stations, so the seismograms are bandpass filtered 1 – 2 Hz. The site amplification effect is determined by comparing the coda envelopes of regional earthquakes at all stations and then removed. A median filter is applied to the absolute amplitude of the bandpass filtered data to remove the spikes of local earthquakes. Day-long data files of each station are detrended and the median value is removed to suppress the effect of storms and local noise. An average of all data files per day is then obtained to amplify the coherent energy from NVT and diminish residual noise. An amplitude cutoff for NVT is empirically determined and applied to all daily data within the study period to generate the NVT catalog. The automatically determined catalog is compared with a catalog created by visual analysis of daily spectrograms. A detailed comparison is done of the month with the greatest difference between the two catalogs, May 2006. It is found that the automatic detection algorithm had fewer false picks and undetermined NVT than the initial visual NVT detection. Thus, the automatic NVT detection algorithm developed has fewer errors and can be effectively used for further analysis of the tremor activity.
Desarrollo de un algoritmo de detección de tremores no-volcánicos (TNV). Un TNV ocurre en el rango de frecuencia de 1 – 10 Hz, pero el ruido ambiental alto ocurre por encima de los 2 Hz en muchas de las estaciones del MesoAmerican Seismic Experiment (MASE), entonces los sismogramas se filtran con un paso banda de 1 – 2 Hz. Se determina el efecto de sitio comparando la ventana de las codas de terremotos regionales en todas las estaciones, y luego se remueve. Se aplica un filtro mediano a la amplitud absoluta de los datos filtrados con el filtro de paso banda para remover los picos de los terremotos locales. Se quita la tendencia y el valor mediano de los archivos de datos de un día para eliminar el efecto de las tormentas y el ruido local. Se obtiene el promedio de todos los datos por día para amplificar la energía coherente de los TNV y para disminuir el ruido local. Se determina empíricamente un límite de amplitud de los TNV y se aplica a todos los datos diariamente del periodo de estudio para generar el catálogo de los TNV. Se compara el catálogo determinado automáticamente con el catálogo creado por el análisis visual de los espectrogramas diariamente. Se hace un análisis preciso durante el mes con la mayor diferencia entre los dos catálogos (mayo de 2006). Encontrandose que el algoritmo de detección automática tuvo menos falsos positivos y menos TNV indeterminados que la detección inicial de TNV visualmente, por lo tanto el algoritmo automático desarrollado de detección de TNV tiene menos errores y puede usarse efectivamente para futuros análisis de la actividad de los tremores.
Idioma: No aplica

Artículos similares:

Ordered Hunt Schemes for Overlaid CDMA Cellular Systems,Esquemas de ordenamiento en sistemas celulares sobrepuestos CDMA por Castañeda Camacho, J; Benemérita Universidad Autónoma de Puebla, Puebla, México,Lara Rodríguez, D; IPN
Model for Adjustment of Aggregate Forecasts using Fuzzy Logic,Modelo para el ajuste de pronósticos agregados utilizando lógica difusa por Escobar Gómez, E N; Instituto Tecnológico de Tuxtla Gutiérrez Chiapas,Díaz Núñez, J J; Universidad Autónoma de Ciudad Juárez Chihuahua,Taracena Sanz, L F; Instituto Tecnológico de Querétaro, Querétaro
Volatile Organic Compound Emissions from Light-Duty Vehicles During Cold-Starts,Emisiones de compuestos orgánicos volátiles durante arranques en frío de automóviles ligeros por Mendoza Domínguez, A; Tecnológico de Monterrey, Campus Monterrey, Nuevo León, México,León Romero, M A; Tecnológico de Monterrey, Campus Monterrey, Nuevo León, México,Caballero Mata, P
Matrix Formulation of Foundations for Vibrating Machinery in Frequency Domain,Formulación matricial de cimentaciones para maquinaria vibratoria en el dominio de la frecuencia por Carbajal Romero, M F; Instituto Politécnico Nacional. México DF,Rodríguez Castellanos, A; Instituto Mexicano del Petróleo. México DF,Rodríguez Sánchez, J E; Instituto Mexicano del Petróleo. México DF,Flores Méndez, E; IPN
Hydrogen Sorption Properties of the Intermetallic Mg2Ni Obtained by Using a Simoloyer Ball Milling,Propiedades de ab-desorción de hidrógeno del intermetálico Mg2Ni obtenido empleando un molino de bolas Simoloyer por Martínez Franco, E; IPN,Klassen, T; GKSS, Research Center Geesthacht, Germany,Jaramillo Vigueras, D; IPN,Bormann, R; GKSS, Research Center Geesthacht, Germany
Numerical Approach to an Outflow Hydrograph of a Dambreak,Estimación numérica del hidrograma de salida de una presa debido a su ruptura por Fuentes Mariles, O A; Universidad Nacional Autónoma de México,Arganis Juárez, M L; UNAM,De Luna Cruz, F; UNAM,Franco, V; UNAM
Electrical Parameters Extraction of CMOS Floating-Gate Inverters,Extracción de parámetros eléctricos de inversores CMOS de compuerta flotante por Molinar Solís, J E; Universidad Autónoma del Estado de México,Ponce Ponce, V H; IPN,García Lozano, R Z; Universidad Autónoma del Estado de México,Díaz Sanchez, A; Instituto Nacional de Astrofísica, Óptica y Electrónica INAOE,Rocha Pérez, j M; Instituto Nacional de Astrofísica, Óptica y Electrónica INAOE
Back Work Ratio of Brayton Cycle,La relación de trabajo de retroceso de un ciclo Brayton por Malaver de la Fuente, M; Universidad Marítima del Caribe, Venezuela
Active Rectifier with Extended Functions: An Option to Voltage Sags Ride Through and Power Quality Improvement,Rectificador activo con funciones ampliadas: una alternativa para la compensación de sags de voltaje y mejorar la calidad de la red eléctrica por Núñez Gutiérrez, C A; Universidad Autónoma de San Luis Potosí, SLP,Lira Pérez, J; Universidad Autónoma de San Luis Potosí, SLP,Pazos Flores, F; Universidad Autónoma de San Luis Potosí, SLP,Echavarría Solís, R; Universidad Politécnica de Victoria, Ciudad Victoria, Tamaulipas
10