Título: A PRELIMINARY THERMAL MODEL OF THE MEXICAN SEISMOVOLCANIC BELT AS A RESULT OF SUBDUCTION
A PRELIMINARY THERMAL MODEL OF THE MEXICAN SEISMOVOLCANIC BELT AS A RESULT OF SUBDUCTION
Autores: A. Lubimova, E.; Inst. Physics of the Earth, Acad. Sci. USSR.
Fecha: 2012-10-05
Publicador: Revistas UNAM
Fuente:
Tipo:

Tema: No aplica
Descripción: A two-dimensional numerical thermal model of the Mexican Volcanic Belt (MVB) is developed. In this model geophysical and geological data are taken into account (heat generation, heat flow, volcanism, fault pattern and geometrical parameters of the assumed Zavaritskiy – Benioff zone), and an additional heat source due to friction is assumed. An increasing effective heat transport is introduced, coinciding with the observed highly faulted region. Using this model the temperature distribution with depth and surface heat flow are determined. The calculated profile Acapulco-Tuxpan shows that heat flow increases from a very low value (33.3 mW/m2) near to the trench, to values of 58.2 mW/m2 in the geothermally active areas, and 108.2 mW/m2 in the region of recent volcanism.
Se desarrolla un modelo térmico de la faja volcánica mexicana. Los datos geofísicos y los datos geológicos se toman en cuenta en el desarrollo de este modelo (generación de calor, flujo de calor, volcanismo, patrón de falla y parámetros geométricos de la supuesta zona de Zavaritsky-Benioff) y además se supone una fuente adicional de calor debida a la fricción. Se introduce en le discusión un transporte de calor efectivo e incrementado de acuerdo con la región estudiada altamente fracturada. Con el empleo de este modelo puede determinarse la distribución de la temperatura según el flujo calórico profundo y superficial. El perfil calculado para Acapulsco-Tuxpan muestra que el flujo de calor aumenta desde un valor muy bajo (33.3 mW/m2) cerca de la trinchera, hasta valores de 58.2 mW/m2 en las áreas geotérmicas activas y hasta 108 mW/m2, en la región de reciente volcanismo.
Idioma: No aplica

Artículos similares:

Ordered Hunt Schemes for Overlaid CDMA Cellular Systems,Esquemas de ordenamiento en sistemas celulares sobrepuestos CDMA por Castañeda Camacho, J; Benemérita Universidad Autónoma de Puebla, Puebla, México,Lara Rodríguez, D; IPN
Model for Adjustment of Aggregate Forecasts using Fuzzy Logic,Modelo para el ajuste de pronósticos agregados utilizando lógica difusa por Escobar Gómez, E N; Instituto Tecnológico de Tuxtla Gutiérrez Chiapas,Díaz Núñez, J J; Universidad Autónoma de Ciudad Juárez Chihuahua,Taracena Sanz, L F; Instituto Tecnológico de Querétaro, Querétaro
Volatile Organic Compound Emissions from Light-Duty Vehicles During Cold-Starts,Emisiones de compuestos orgánicos volátiles durante arranques en frío de automóviles ligeros por Mendoza Domínguez, A; Tecnológico de Monterrey, Campus Monterrey, Nuevo León, México,León Romero, M A; Tecnológico de Monterrey, Campus Monterrey, Nuevo León, México,Caballero Mata, P
Matrix Formulation of Foundations for Vibrating Machinery in Frequency Domain,Formulación matricial de cimentaciones para maquinaria vibratoria en el dominio de la frecuencia por Carbajal Romero, M F; Instituto Politécnico Nacional. México DF,Rodríguez Castellanos, A; Instituto Mexicano del Petróleo. México DF,Rodríguez Sánchez, J E; Instituto Mexicano del Petróleo. México DF,Flores Méndez, E; IPN
Hydrogen Sorption Properties of the Intermetallic Mg2Ni Obtained by Using a Simoloyer Ball Milling,Propiedades de ab-desorción de hidrógeno del intermetálico Mg2Ni obtenido empleando un molino de bolas Simoloyer por Martínez Franco, E; IPN,Klassen, T; GKSS, Research Center Geesthacht, Germany,Jaramillo Vigueras, D; IPN,Bormann, R; GKSS, Research Center Geesthacht, Germany
Numerical Approach to an Outflow Hydrograph of a Dambreak,Estimación numérica del hidrograma de salida de una presa debido a su ruptura por Fuentes Mariles, O A; Universidad Nacional Autónoma de México,Arganis Juárez, M L; UNAM,De Luna Cruz, F; UNAM,Franco, V; UNAM
Electrical Parameters Extraction of CMOS Floating-Gate Inverters,Extracción de parámetros eléctricos de inversores CMOS de compuerta flotante por Molinar Solís, J E; Universidad Autónoma del Estado de México,Ponce Ponce, V H; IPN,García Lozano, R Z; Universidad Autónoma del Estado de México,Díaz Sanchez, A; Instituto Nacional de Astrofísica, Óptica y Electrónica INAOE,Rocha Pérez, j M; Instituto Nacional de Astrofísica, Óptica y Electrónica INAOE
Back Work Ratio of Brayton Cycle,La relación de trabajo de retroceso de un ciclo Brayton por Malaver de la Fuente, M; Universidad Marítima del Caribe, Venezuela
Active Rectifier with Extended Functions: An Option to Voltage Sags Ride Through and Power Quality Improvement,Rectificador activo con funciones ampliadas: una alternativa para la compensación de sags de voltaje y mejorar la calidad de la red eléctrica por Núñez Gutiérrez, C A; Universidad Autónoma de San Luis Potosí, SLP,Lira Pérez, J; Universidad Autónoma de San Luis Potosí, SLP,Pazos Flores, F; Universidad Autónoma de San Luis Potosí, SLP,Echavarría Solís, R; Universidad Politécnica de Victoria, Ciudad Victoria, Tamaulipas