Título: RADAR PRECIPITATION ECHO MOTION IN HURRICANE DONNA
MOVIMIENTO DEL ECO DE PRECIPITACION EN RADAR DEL HURACAN DONNA
Autores: SENN, H. V.
Fecha: 2013-01-16
Publicador: Revistas UNAM
Fuente:
Tipo:

Tema: No aplica
Descripción: Radar data consisting of about 3,800 precipitation echoes were obtained by analyzing film from several radars during the same time period in Hurricane Donna. These data are combined to illustrate for the first time the complete field of relatively simultaneous echo motion at almost all ranges and azimuths in a hurricane. The field of radar echo motion in Hurricane Donna on 9 September 1960 is then compared with local surface and other winds; and also on 9 an d 10 September with radar precipitation echo motion data from Hurricanes Edna 1954, Connie, Diane and lone 1955, Audrey 1957, and Daisy and Helene 1958, When storm center velocity is eliminated, it is shown that the resulting relative echo motion maximums  occur most often to the left of the direction. Possible explanations for this echo motion behavior are discussed.
Analizando películas de varios radares del mismo tiempo en el Huracàn Donna, se obtuvieron datos consistentes en casi 3,800 ecos de precipitación que se combinaron para ilustrar, por primera vez, el campo completo de movimiento de ecos relativamente simultáneos en casi todas las alturas y azimutes de un huracán. El campo de los movimientos de eco en radar del Huracàn Donna, el 9 de Septiembre  de 1960, se comparó después con vientos locales de superficies y otros y también el 9 y 10 de Septiembre con datos de movimientos de eco de precipitación en radar en los Huracanes Edna 1954, Connie, Dinna e lone 1955, Audrey 1957 y Daisy y Helene 1958. Cuando se elimina la velocidad del centro de la tormenta, puede comprobarse que los máximos del movimiento de eco relativo resultante tienen lugar con màs frecuencia a la izquierda de esa dirección, se discuten posibles explicaciones para este comportamiento del movimiento de eco.
Idioma: No aplica

Artículos similares:

Ordered Hunt Schemes for Overlaid CDMA Cellular Systems,Esquemas de ordenamiento en sistemas celulares sobrepuestos CDMA por Castañeda Camacho, J; Benemérita Universidad Autónoma de Puebla, Puebla, México,Lara Rodríguez, D; IPN
Model for Adjustment of Aggregate Forecasts using Fuzzy Logic,Modelo para el ajuste de pronósticos agregados utilizando lógica difusa por Escobar Gómez, E N; Instituto Tecnológico de Tuxtla Gutiérrez Chiapas,Díaz Núñez, J J; Universidad Autónoma de Ciudad Juárez Chihuahua,Taracena Sanz, L F; Instituto Tecnológico de Querétaro, Querétaro
Volatile Organic Compound Emissions from Light-Duty Vehicles During Cold-Starts,Emisiones de compuestos orgánicos volátiles durante arranques en frío de automóviles ligeros por Mendoza Domínguez, A; Tecnológico de Monterrey, Campus Monterrey, Nuevo León, México,León Romero, M A; Tecnológico de Monterrey, Campus Monterrey, Nuevo León, México,Caballero Mata, P
Matrix Formulation of Foundations for Vibrating Machinery in Frequency Domain,Formulación matricial de cimentaciones para maquinaria vibratoria en el dominio de la frecuencia por Carbajal Romero, M F; Instituto Politécnico Nacional. México DF,Rodríguez Castellanos, A; Instituto Mexicano del Petróleo. México DF,Rodríguez Sánchez, J E; Instituto Mexicano del Petróleo. México DF,Flores Méndez, E; IPN
Hydrogen Sorption Properties of the Intermetallic Mg2Ni Obtained by Using a Simoloyer Ball Milling,Propiedades de ab-desorción de hidrógeno del intermetálico Mg2Ni obtenido empleando un molino de bolas Simoloyer por Martínez Franco, E; IPN,Klassen, T; GKSS, Research Center Geesthacht, Germany,Jaramillo Vigueras, D; IPN,Bormann, R; GKSS, Research Center Geesthacht, Germany
Numerical Approach to an Outflow Hydrograph of a Dambreak,Estimación numérica del hidrograma de salida de una presa debido a su ruptura por Fuentes Mariles, O A; Universidad Nacional Autónoma de México,Arganis Juárez, M L; UNAM,De Luna Cruz, F; UNAM,Franco, V; UNAM
Electrical Parameters Extraction of CMOS Floating-Gate Inverters,Extracción de parámetros eléctricos de inversores CMOS de compuerta flotante por Molinar Solís, J E; Universidad Autónoma del Estado de México,Ponce Ponce, V H; IPN,García Lozano, R Z; Universidad Autónoma del Estado de México,Díaz Sanchez, A; Instituto Nacional de Astrofísica, Óptica y Electrónica INAOE,Rocha Pérez, j M; Instituto Nacional de Astrofísica, Óptica y Electrónica INAOE
Back Work Ratio of Brayton Cycle,La relación de trabajo de retroceso de un ciclo Brayton por Malaver de la Fuente, M; Universidad Marítima del Caribe, Venezuela
Active Rectifier with Extended Functions: An Option to Voltage Sags Ride Through and Power Quality Improvement,Rectificador activo con funciones ampliadas: una alternativa para la compensación de sags de voltaje y mejorar la calidad de la red eléctrica por Núñez Gutiérrez, C A; Universidad Autónoma de San Luis Potosí, SLP,Lira Pérez, J; Universidad Autónoma de San Luis Potosí, SLP,Pazos Flores, F; Universidad Autónoma de San Luis Potosí, SLP,Echavarría Solís, R; Universidad Politécnica de Victoria, Ciudad Victoria, Tamaulipas
10