Título: PRELIMINARY ANALYSIS OF THERMAL ANOMALIES BEFORE THE 2010 BAJA CALIFORNIA M7.2 EARTHQUAKE
PRELIMINARY ANALYSIS OF THERMAL ANOMALIES BEFORE THE 2010 BAJA CALIFORNIA M7.2 EARTHQUAKE
Autores: Jie, Yang; Remote Sensing Center, Nanyang Normal University, China
Guanmeng, Guo; Remote Sensing Center, Nanyang Normal University, China
Fecha: 2013-09-30
Publicador: Revistas UNAM
Fuente:
Tipo:

Tema: Earthquake anomaly recognition, air temperature, NCEP-FNL, AMSR-E.
Earthquake anomaly recognition, air temperature, NCEP-FNL, AMSR-E.
Descripción: This paper presents a preliminary analysis of thermal anomalies before the Baja California M7.2 earthquake occurred on April 4, 2010. The results show that surface air temperature of the Mexicali station, which is the closest one to the epicenter, reaches its maximum value on March 30, which is also the maximum value from January 1 to April 10, 2010. Weather stations far away from the epicenter (100 km away) show no other thermal anomaly. In particular, the National Centers for Environmental Prediction Final Operational Global Analysis (NCEP-FNL) air temperature data show a maximum temperature change between March 30 and 31 at the epicenter grid point, while the other surrounding 7199 grid points show medium to low temperature change. The microwave brightness temperature measured by the Advanced Microwave Scanning Radiometer on board the EOS Aqua satellite (AMSR-E) also shows an increase on March 31. The results of multiple thermal parameters analysis obey well the DTS criterions: deviation (D), time synchronism (T), and space consistency (S), so they can be considered as convincing seismic thermal anomalies. This analysis might contribute to make reliable earthquake predictions.
Este trabajo presenta un análisis preliminar de las anomalía térmicas observadas antes del terremoto de magnitud 7.2 ocurrido el 4 de abril de 2010 en Baja California. Los resultados muestran que la temperatura superficial del aire en la estación de Mexicali (la más cercana al epicentro) alcanza un valor máximo el 30 de marzo (que también es el máximo registrado entre el 1 de enero y el 4 de abril de 2010). Las estaciones meteorológicas lejanas al epicentro (distantes 100 km de éste) no muestran otra anomalía. En particular, los datos de temperatura del aire del Análisis Final de los Centros Nacionales de Predicción Ambiental (NCEP-FNA, por sus siglas en inglés) muestran un cambio máximo de temperatura entre el 30 y 31 de marzo en el punto de malla del epicentro, en tanto que los otros 7199 puntos de malla muestran cambios medianos a bajos. La temperatura de la brillantez medida por el radiómetro avanzado de barrido por microondas, acoplado al sistema de observación de la Tierra del satélite Aqua (AMSR-E, por sus siglas en inglés) también muestra un incremento el 31 de marzo. Los resultados del análisis térmico multiparamétrico cumplen de manera adecuada con los criterios DTS (desviación [D], sincronía temporal [T] y consistencia espacial [S]), de manera que pueden considerarse como anomalías térmicas sísmicas. Este análisis podría contribuir al pronóstico confiable de terremotos.
Idioma: Inglés

Artículos similares:

Ordered Hunt Schemes for Overlaid CDMA Cellular Systems,Esquemas de ordenamiento en sistemas celulares sobrepuestos CDMA por Castañeda Camacho, J; Benemérita Universidad Autónoma de Puebla, Puebla, México,Lara Rodríguez, D; IPN
Model for Adjustment of Aggregate Forecasts using Fuzzy Logic,Modelo para el ajuste de pronósticos agregados utilizando lógica difusa por Escobar Gómez, E N; Instituto Tecnológico de Tuxtla Gutiérrez Chiapas,Díaz Núñez, J J; Universidad Autónoma de Ciudad Juárez Chihuahua,Taracena Sanz, L F; Instituto Tecnológico de Querétaro, Querétaro
Volatile Organic Compound Emissions from Light-Duty Vehicles During Cold-Starts,Emisiones de compuestos orgánicos volátiles durante arranques en frío de automóviles ligeros por Mendoza Domínguez, A; Tecnológico de Monterrey, Campus Monterrey, Nuevo León, México,León Romero, M A; Tecnológico de Monterrey, Campus Monterrey, Nuevo León, México,Caballero Mata, P
Matrix Formulation of Foundations for Vibrating Machinery in Frequency Domain,Formulación matricial de cimentaciones para maquinaria vibratoria en el dominio de la frecuencia por Carbajal Romero, M F; Instituto Politécnico Nacional. México DF,Rodríguez Castellanos, A; Instituto Mexicano del Petróleo. México DF,Rodríguez Sánchez, J E; Instituto Mexicano del Petróleo. México DF,Flores Méndez, E; IPN
Hydrogen Sorption Properties of the Intermetallic Mg2Ni Obtained by Using a Simoloyer Ball Milling,Propiedades de ab-desorción de hidrógeno del intermetálico Mg2Ni obtenido empleando un molino de bolas Simoloyer por Martínez Franco, E; IPN,Klassen, T; GKSS, Research Center Geesthacht, Germany,Jaramillo Vigueras, D; IPN,Bormann, R; GKSS, Research Center Geesthacht, Germany
Numerical Approach to an Outflow Hydrograph of a Dambreak,Estimación numérica del hidrograma de salida de una presa debido a su ruptura por Fuentes Mariles, O A; Universidad Nacional Autónoma de México,Arganis Juárez, M L; UNAM,De Luna Cruz, F; UNAM,Franco, V; UNAM
Electrical Parameters Extraction of CMOS Floating-Gate Inverters,Extracción de parámetros eléctricos de inversores CMOS de compuerta flotante por Molinar Solís, J E; Universidad Autónoma del Estado de México,Ponce Ponce, V H; IPN,García Lozano, R Z; Universidad Autónoma del Estado de México,Díaz Sanchez, A; Instituto Nacional de Astrofísica, Óptica y Electrónica INAOE,Rocha Pérez, j M; Instituto Nacional de Astrofísica, Óptica y Electrónica INAOE
Back Work Ratio of Brayton Cycle,La relación de trabajo de retroceso de un ciclo Brayton por Malaver de la Fuente, M; Universidad Marítima del Caribe, Venezuela
Active Rectifier with Extended Functions: An Option to Voltage Sags Ride Through and Power Quality Improvement,Rectificador activo con funciones ampliadas: una alternativa para la compensación de sags de voltaje y mejorar la calidad de la red eléctrica por Núñez Gutiérrez, C A; Universidad Autónoma de San Luis Potosí, SLP,Lira Pérez, J; Universidad Autónoma de San Luis Potosí, SLP,Pazos Flores, F; Universidad Autónoma de San Luis Potosí, SLP,Echavarría Solís, R; Universidad Politécnica de Victoria, Ciudad Victoria, Tamaulipas
10