Título: Analyzing ground ozone formation regimes using a principal axis factoring method: A case study of Kladno (Czech Republic) industrial area
Analyzing ground ozone formation regimes using a principal axis factoring method: A case study of Kladno (Czech Republic) industrial area
Autores: MALEC, L.
SKÁCEL, F.
FOUSEK, T.
TEKÁC, V.
KRÁL, P.
Fecha: 1969-12-31
Publicador: Revistas UNAM
Fuente:
Tipo:

Tema: Air pollution, ozone, discriminant analysis, factor analysis
;AIR POLLUTION; OZONE; DISCRIMINANT ANALYSIS; FACTOR ANALYSIS
Descripción: Tropospheric ozone is a secondary air pollutant, changes in the ambient content of which are affected by both, the emission rates of primary pollutants and the variability of meteorological conditions. In this paper, we use two multivariate statistical methods to analyze the impact of the meteorological conditions associated with pollutant transformation processes. First, we evaluated the variability of the spatial and temporal distribution of ozone precursor parameters by using discriminant analysis (DA) in locations close to the industrial area of Kladno (a city in the Czech Republic). Second, we interpreted the data set by using factor analysis (FA) to examine the differences between ozone formation processes in summer and in winter. To avoid temperature dependency between the variables, as well as to describe tropospheric washout processes, we used water vapour content rather than the more commonly employed relative humidity parameter. In this way, we were able to successfully determine and subsequently evaluate the various processes of ozone formation, together with the distribution of ozone precursors. High air temperature, radiation and low water content relate to summer pollution episodes, while radiation and wind speed prove to be the most important parameters during winter.  
EL OZONO TROPOSFÉRICO ES UN CONTAMINANTE FOTOQUÍMICO SECUNDARIO CUYOS CONTENIDOS ESTÁN INFLUIDOS TANTO POR LAS RAZONES DE EMISIÓN DE LAS SUSTANCIAS CONTAMINANTES PRIMARIAS COMO POR LA VARIABILIDAD DE LAS CONDICIONES METEOROLÓGICAS. EN ESTE TRABAJO UTILIZAMOS DOS MÉTODOS ESTADÍSTICOS MULTIVARIADOS PARA EL ANÁLISIS DE LA INFLUENCIA DE LAS CONDICIONES METEOROLÓGICAS RELACIONADAS CON LOS PROCESOS DE TRANSFORMACIÓN DE LAS SUSTANCIAS CONTAMINANTES. PRIMERO, ESTIMAMOS LA VARIABILIDAD DE LA DESCOMPOSICIÓN ESPACIAL Y TEMPORAL DE LOS PRECURSORES DE OZONO MEDIANTE EL ANÁLISIS DISCRIMINANTE (DA) EN LAS ÁREAS CERCANAS A LA ZONA INDUSTRIAL DE KLADNO (UNA CIUDAD DE LA REPÚBLICA CHECA). SEGUNDO, INTERPRETAMOS UN CONJUNTO DE DATOS MEDIANTE EL ANÁLISIS FACTORIAL (FA) PARA EXAMINAR LAS DIFERENCIAS ENTRE LOS PROCESOS DE GENERACIÓN DE OZONO ENTRE LAS ÉPOCAS DE VERANO E INVIERNO. PARA EVITAR LA DEPENDENCIA DE LA TEMPERATURA DE LAS VARIABLES, ASÍ COMO PARA DESCRIBIR LOS PROCESOS TROPOSFÉRICOS DE LAVADO DE LAS SUSTANCIAS CONTAMINANTES, UTILIZAMOS EL CONTENIDO DE VAPOR DE AGUA EN VEZ DEL PARÁMETRO DE HUMEDAD RELATIVA, EMPLEADO MUY A MENUDO. DE ESTA MANERA FUIMOS CAPACES DE DEFINIR CON ÉXITO LOS DIFERENTES PROCESOS DE GENERACIÓN DE OZONO Y POSTERIORMENTE ESTIMARLOSBAJO CONTENIDO DE AGUA ESTÁN RELACIONADOS CON LOS EPISODIOS DE CONTAMINACIÓN EN VERANO, MIENTRAS QUE LA RADIACIÓN Y LA VELOCIDAD DEL VIENTO RESULTAN SER LOS PARÁMETROS MÁS IMPORTANTES DURANTE EL INVIERNO.
Idioma: Inglés

Artículos similares:

Ordered Hunt Schemes for Overlaid CDMA Cellular Systems,Esquemas de ordenamiento en sistemas celulares sobrepuestos CDMA por Castañeda Camacho, J; Benemérita Universidad Autónoma de Puebla, Puebla, México,Lara Rodríguez, D; IPN
Model for Adjustment of Aggregate Forecasts using Fuzzy Logic,Modelo para el ajuste de pronósticos agregados utilizando lógica difusa por Escobar Gómez, E N; Instituto Tecnológico de Tuxtla Gutiérrez Chiapas,Díaz Núñez, J J; Universidad Autónoma de Ciudad Juárez Chihuahua,Taracena Sanz, L F; Instituto Tecnológico de Querétaro, Querétaro
Volatile Organic Compound Emissions from Light-Duty Vehicles During Cold-Starts,Emisiones de compuestos orgánicos volátiles durante arranques en frío de automóviles ligeros por Mendoza Domínguez, A; Tecnológico de Monterrey, Campus Monterrey, Nuevo León, México,León Romero, M A; Tecnológico de Monterrey, Campus Monterrey, Nuevo León, México,Caballero Mata, P
Matrix Formulation of Foundations for Vibrating Machinery in Frequency Domain,Formulación matricial de cimentaciones para maquinaria vibratoria en el dominio de la frecuencia por Carbajal Romero, M F; Instituto Politécnico Nacional. México DF,Rodríguez Castellanos, A; Instituto Mexicano del Petróleo. México DF,Rodríguez Sánchez, J E; Instituto Mexicano del Petróleo. México DF,Flores Méndez, E; IPN
Hydrogen Sorption Properties of the Intermetallic Mg2Ni Obtained by Using a Simoloyer Ball Milling,Propiedades de ab-desorción de hidrógeno del intermetálico Mg2Ni obtenido empleando un molino de bolas Simoloyer por Martínez Franco, E; IPN,Klassen, T; GKSS, Research Center Geesthacht, Germany,Jaramillo Vigueras, D; IPN,Bormann, R; GKSS, Research Center Geesthacht, Germany
Numerical Approach to an Outflow Hydrograph of a Dambreak,Estimación numérica del hidrograma de salida de una presa debido a su ruptura por Fuentes Mariles, O A; Universidad Nacional Autónoma de México,Arganis Juárez, M L; UNAM,De Luna Cruz, F; UNAM,Franco, V; UNAM
Electrical Parameters Extraction of CMOS Floating-Gate Inverters,Extracción de parámetros eléctricos de inversores CMOS de compuerta flotante por Molinar Solís, J E; Universidad Autónoma del Estado de México,Ponce Ponce, V H; IPN,García Lozano, R Z; Universidad Autónoma del Estado de México,Díaz Sanchez, A; Instituto Nacional de Astrofísica, Óptica y Electrónica INAOE,Rocha Pérez, j M; Instituto Nacional de Astrofísica, Óptica y Electrónica INAOE
Back Work Ratio of Brayton Cycle,La relación de trabajo de retroceso de un ciclo Brayton por Malaver de la Fuente, M; Universidad Marítima del Caribe, Venezuela
Active Rectifier with Extended Functions: An Option to Voltage Sags Ride Through and Power Quality Improvement,Rectificador activo con funciones ampliadas: una alternativa para la compensación de sags de voltaje y mejorar la calidad de la red eléctrica por Núñez Gutiérrez, C A; Universidad Autónoma de San Luis Potosí, SLP,Lira Pérez, J; Universidad Autónoma de San Luis Potosí, SLP,Pazos Flores, F; Universidad Autónoma de San Luis Potosí, SLP,Echavarría Solís, R; Universidad Politécnica de Victoria, Ciudad Victoria, Tamaulipas
10