Título: Cooling and heating due to latent and sensible heat over the Yucatan continental shelf
Cooling and heating due to latent and sensible heat over the Yucatan continental shelf
Autores: HERNÁNDEZ TÉLLEZ, J.
ALDECO RAMÍREZ, J.
SALAS DE LEÓN, DAVID ALBERTO
Fecha: 1969-12-31
Publicador: Revistas UNAM
Fuente:
Tipo:

Tema: No aplica
Descripción: A PARTIR DE DATOS METEREOLÓGICOS Y DE TEMPERATURA SUPERFICIAL DEL MAR (SST), OBTENIDOS SOBRE LA PLATAFORMA CONTINENTAL DE YUCATÁN, DURANTE LOS CRUCEROS OCEANOGRÁFICOS PLAYUC (DEL 6 AL 17 DE ENERO DE 1990) Y YUCPLA (DEL 25 DE MAYO AL 4 DE JUNIO DE 1990), SE CALCULARON LAS ÁREAS DE ENFRIAMIENTO Y CALENTAMIENTO PRODUCIDAS POR EL FLUJO DE CALOR LATENTE (QE) Y SENSIBLE (QT). LOS CÁLCULOS SE REALIZARON USANDO LAS ECUACIONES AERODINÁMICAS DE FLUJO TURBULENTO. DURANTE PLAYUC LA LÍNEA DE SST -TA = 0(TEMPERATURA DEL MAR MENOS DEL AIRE) DIVIDIÓ EL ÁREA DE ESTUDIO EN DOS REGIONES (ESTE Y OESTE). ESTO FUE CAUSADO POR DOS NORTES MODERADOS. EN EL LADO OESTE LA DIFERENCIA SST-TA VARIO ENTRE 1 Y 4°C; EN EL LADO INFERIOR ESTA DIFERENCIA VARIO ENTRE -1 Y 3°C. LOS VALORES DE QE Y QT PARA LA REGIÓN DE ENFRIAMIENTO AL OESTE FUERON DESDE 160 HASTA 260W/M Y DESDE 10 HASTA 60 W/M, RESPECTIVAMENTE. EN EL LADO ESTE EL CONTRASTE DIURNO Q FUE OBSERVADO EN TRES ÁREAS PEQUEÑAS. AL NORTE DE CABO CATOCHE LA BRUMA PRESENTE SOBRE LA REGIÓN DE DÉBIL SURGENCIA, DISMINUYO LA CANTIDAD DE ENFRIAMIENTO POR Q DESDE 30 A MENOS DE 10 W/M Y LA CANTIDAD DE CALENTAMIENTO POR Q A VALORES DE ALREDEDOR DE -5 A -6 W/M. EL VALOR PROMEDIO DE QE Y QT SOBRE LA PLATAFORMA DURANTE PLAYUC FUE DE 140.92 Y 14.88 W/M2, RESPECTIVAMENTE. DURANTE YUCPLA SE OBSERVO LA INFLUENCIA DE AIRE HÚMEDO Y CALIDO DEL ESTE. DOS LÍNEAS DE SST -TA=0 DIVIDIERON DIAGONALMENTE LA REGION EN DOS PORCIONES, UNA NOROESTE Y OTRA SURESTE. PARA LA REGIÓN NOROESTE LA DIFERENCIA SST -TA VARIO ENTRE -1 Y 0°C; PARA LA SURESTE ENTRE -4 Y 0°C. DURANTE ESTE SEGUNDO CRUCERO EL ENFRIAMIENTO FUE MENOS FUERTE Y CON UN DÉBIL CONTRASTE ESPACIAL. EN LA REGIÓN NW SE OBSERVARON DOS INTRUSIONES DE QE , UNA HACIA LA COSTA Y OTRA HACIA EL MAR; EN LA REGIÓN SE TAMBIÉN SE OBSERVO UNA LENGUA ORIENTADA DE NORTE A SUR. SIMILARMENTE A LO QUE OCURRIÓ EN PLAYUC, LA REGIÓN DE SURGENCIA Y BRUMA PROMOVIÓ UN CALENTAMIENTO DEBIDO A CONDENSACIÓN (Q
From meteorological data and sea surface temperatures taken during the oceanographic cruises PLAYUC (January 6 to 17, 1990) and YUCPLA (May 25 to June 4, 1990), conducted over the Yucatan Continental Shelf, the cooling and heating areas produced by the fluxes of latent (Qe) and sensible heat (Qt) were determined. The computation was done using the bulk aerodynamic equations. During PLAYUC, the line of SST - Ta = 0 (sea surface temperature minus air temperature) divided roughly the study area into two regions (east and west). This was caused by two moderated northers. At the west side the difference SST - Ta was between 1 and 4ºC, and at the lower east side the difference was between -1 to -3ºC. The values of Qe and Qt for the cooling area at the west were from 160 to 260 W/m2 and from 10 to 60 W/m2 respectively. At the east portion the diurnal contrast of Qe was observed at three small areas. North of Cabo Catoche a fog was present over a weak upwelling area, reducing the cooling rate due to Qe from 30 to below 10 W/m3 and the heating due to Qt to values around -5 to -6 W/m2. The average values during PLAYUC for Qe and Qt over the shelf were 140.92 and 14.88 W/m2, respectively. During YUCPLA, influence of moist and warm air from the East was observed. Two lines of SST - Ta = 0 divided the study area diagonally in two portions, northwest and southeast. The difference SST - Ta for the northwest portion was from -1 to 0ºC and for the southeast from -4 to 0ºC. During this second cruise the cooling was less intense and with weaker spatial contrast. At the NW portion two intrusions of Qe were observed, one toward the coast and another going offshore. At the SE portion a north-to-south tongue was observed. Similar to what was the case during PLAYUC, the upwelling and fog area promoted a heating due to condensation (Qe < 0). At the NW portion three well delineated regions of heating and cooling were observed, showing the diurnal variations. The average values during this cruise for Qe and Qt were 66.63 and 0.36 W/m2, respectively.
Idioma: Inglés

Artículos similares:

Ordered Hunt Schemes for Overlaid CDMA Cellular Systems,Esquemas de ordenamiento en sistemas celulares sobrepuestos CDMA por Castañeda Camacho, J; Benemérita Universidad Autónoma de Puebla, Puebla, México,Lara Rodríguez, D; IPN
Model for Adjustment of Aggregate Forecasts using Fuzzy Logic,Modelo para el ajuste de pronósticos agregados utilizando lógica difusa por Escobar Gómez, E N; Instituto Tecnológico de Tuxtla Gutiérrez Chiapas,Díaz Núñez, J J; Universidad Autónoma de Ciudad Juárez Chihuahua,Taracena Sanz, L F; Instituto Tecnológico de Querétaro, Querétaro
Volatile Organic Compound Emissions from Light-Duty Vehicles During Cold-Starts,Emisiones de compuestos orgánicos volátiles durante arranques en frío de automóviles ligeros por Mendoza Domínguez, A; Tecnológico de Monterrey, Campus Monterrey, Nuevo León, México,León Romero, M A; Tecnológico de Monterrey, Campus Monterrey, Nuevo León, México,Caballero Mata, P
Matrix Formulation of Foundations for Vibrating Machinery in Frequency Domain,Formulación matricial de cimentaciones para maquinaria vibratoria en el dominio de la frecuencia por Carbajal Romero, M F; Instituto Politécnico Nacional. México DF,Rodríguez Castellanos, A; Instituto Mexicano del Petróleo. México DF,Rodríguez Sánchez, J E; Instituto Mexicano del Petróleo. México DF,Flores Méndez, E; IPN
Hydrogen Sorption Properties of the Intermetallic Mg2Ni Obtained by Using a Simoloyer Ball Milling,Propiedades de ab-desorción de hidrógeno del intermetálico Mg2Ni obtenido empleando un molino de bolas Simoloyer por Martínez Franco, E; IPN,Klassen, T; GKSS, Research Center Geesthacht, Germany,Jaramillo Vigueras, D; IPN,Bormann, R; GKSS, Research Center Geesthacht, Germany
Numerical Approach to an Outflow Hydrograph of a Dambreak,Estimación numérica del hidrograma de salida de una presa debido a su ruptura por Fuentes Mariles, O A; Universidad Nacional Autónoma de México,Arganis Juárez, M L; UNAM,De Luna Cruz, F; UNAM,Franco, V; UNAM
Electrical Parameters Extraction of CMOS Floating-Gate Inverters,Extracción de parámetros eléctricos de inversores CMOS de compuerta flotante por Molinar Solís, J E; Universidad Autónoma del Estado de México,Ponce Ponce, V H; IPN,García Lozano, R Z; Universidad Autónoma del Estado de México,Díaz Sanchez, A; Instituto Nacional de Astrofísica, Óptica y Electrónica INAOE,Rocha Pérez, j M; Instituto Nacional de Astrofísica, Óptica y Electrónica INAOE
Back Work Ratio of Brayton Cycle,La relación de trabajo de retroceso de un ciclo Brayton por Malaver de la Fuente, M; Universidad Marítima del Caribe, Venezuela
Active Rectifier with Extended Functions: An Option to Voltage Sags Ride Through and Power Quality Improvement,Rectificador activo con funciones ampliadas: una alternativa para la compensación de sags de voltaje y mejorar la calidad de la red eléctrica por Núñez Gutiérrez, C A; Universidad Autónoma de San Luis Potosí, SLP,Lira Pérez, J; Universidad Autónoma de San Luis Potosí, SLP,Pazos Flores, F; Universidad Autónoma de San Luis Potosí, SLP,Echavarría Solís, R; Universidad Politécnica de Victoria, Ciudad Victoria, Tamaulipas
10