Título: Efectividad clínica de mallas de alginato de sodio para el control de la diseminación de infección con Escherichia coli y Staphylococcus epidermidis en heridas cavitadas con cierre primario en ratas
Clinical efficacy of sodium alginate meshes for the control of infectious dissemination by Escherichia coli and Staphylococcus epidermidis in cavitated wounds with primary healing
Autores: Luna del Villar Velasco, Jorge; Departamento de Medicina, Cirugía y Zootecnia para Pequeñas Especies, Facultad de Medicina Veterinaria y Zootecnia, Universidad Nacional Autónoma de México.
Bernard Bernard, María José; Departamento de Farmacia, Facultad de Química, Universidad Nacional Autónoma de México
Tapia Pérez, Graciela; Departamento de Genética y Bioestadística, Facultad de Medicina Veterinaria y Zootecnia, Universidad Nacional Autónoma de México
Gutiérrez Olvera, Lilia; Departamento de Fisiología y Farmacología, Facultad de Medicina Veterinaria y Zootecnia, Universidad Nacional Autónoma de México
Sumano López, Héctor; Departamento de Fisiología y Farmacología, Facultad de Medicina Veterinaria y Zootecnia, Universidad Nacional Autónoma de México.
Fecha: 2012-12-15
Publicador: Revistas UNAM
Fuente:
Tipo:

Tema: alginato; heridas cavitadas; hidrogeles; malla quirúrgica;
alginate, cavitated wounds, hidrogel, surgical mesh;
Descripción: Se determinó el efecto potencial de cicatrización de mallas de alginato de sodio (AS) en heridas cavitadas infectadas con Escherichia coli y Staphylococcus epidermidis, y se evaluó histopatológica y macroscópicamente la diseminación del proceso infeccioso, formación de granuloma e irritación de los tejidos adyacentes. Se formaron 5 grupos de 24 ratas Wis­tar hembras de 280 ± 34 g de la siguiente manera: grupo testigo con malla de AS sin inóculo; testigo con inóculo de Escherichia coli sin malla; otro grupo testigo con inóculo de Staphylococcus epidermidis, sin malla; grupo con malla de AS + inóculo de Escherichia coli; grupo con malla de AS + inóculo de Staphylococcus epidermidis. Bajo anestesia se realizaron las incisiones en los flancos absominales y se formaron los grupos. Se realizó un seguimiento macroscópico e histopatológico de la zona afectada y se encontró que la presencia de mallas de AS evita o disminuye drásticamen te, tanto la diseminación de la infección a tejidos adyacentes como su irritación. Ello ocurre aun en presencia de Es­cherichia coli o de Staphylococcus epidermidis. En los grupos testigo con malla de AS sin inóculo, testigo con inóculo de Escherichia coli sin malla, otro grupo testigo con inóculo de Staphylococcus epidermidis sin malla y el grupo con malla de AS + inóculo de Escherichia coli, la reepitelización y la reducción en la herida fueron superiores a los grupos que fueron inoculados con Staphylococcus epidermidis. Los odd ratios generales mostraron que el riesgo de disemina­ción fue 58 veces menor con el uso de malla de AS y E. coli como organismo infectante (IC 95% 6.2-210). Los resul­tados encontrados indican que la malla de AS es capaz de proporcionar condiciones adecuadas para la formación de tejido de granulación, sin irritación en los tejidos adyacentes y evitando la diseminación de la infección en heridas cavi­tadas y contaminadas por E. coli y por Staphylococcus epidermidis en ratas. Sin embargo, la presencia de granuloma puede significar una desventaja cicatrizal o estética, como se observó en el grupo testigo con malla de AS sin inóculo.
The potential wound healing ability of sodium alginate (SA) meshes was determined in cavitated rat wounds infected either with Escherichia coli or Staphylococcus epidermidis. Wound progress was evaluated macroscopically and histopathologi­cally to assess dissemination of the induced infection through evaluation of granuloma formation and adjacent tissue ir­ritation. Five groups of 24 female Wistar rats weighing 280 ± 34 g were formed as follows: control group with SA mesh without inoculum, control group with Escherichia coli inoculum without SA mesh, control group with Staphylococcus epi­dermidis inoculum without mesh, group with SA mesh + Escherichia coli inoculum and group with SA mesh + Staphy­lococcus epidermidis inoculum. Abdominal flank incisions were performed under anaesthesia and groups were formed. Both macroscopic and histopathological follow up were carried out and results indicated that the presence of SA meshes avoids or greatly diminishes bacteria dissemination and adjacent tissue irritation. This reaction occurs even in the pres­ence of Escherichia coli or Staphylococcus epidermidis. In the control groups with SA mesh without inoculum and in the groups with Escherichia coli inoculum without SA mesh, and control group with Staphylococcus epidermis inoculum without mesh and group with SA mesh + Escherichia coli inoculum re-epithelialization and wound healing aspect were better than in groups inoculated with Staphylococcus epidermidis, the general odd ratios showed that the dissemination risk was 58 times greater in treatment with SA mesh and E. coli as infectious agent (IC 95% 6.2-210). These results indicate that SA mesh is capable of providing adequate conditions to allow granulation of cavitated wounds, without irritation to adjacent tissues and avoiding dissemination of the infection by E. coli and Staphylococcus epidermidis in rats. However, presence of granuloma can be a healing or esthetic disadvantage, as observed in control group with SA mesh without inoculum.
Idioma: Español

Artículos similares:

Ordered Hunt Schemes for Overlaid CDMA Cellular Systems,Esquemas de ordenamiento en sistemas celulares sobrepuestos CDMA por Castañeda Camacho, J; Benemérita Universidad Autónoma de Puebla, Puebla, México,Lara Rodríguez, D; IPN
Model for Adjustment of Aggregate Forecasts using Fuzzy Logic,Modelo para el ajuste de pronósticos agregados utilizando lógica difusa por Escobar Gómez, E N; Instituto Tecnológico de Tuxtla Gutiérrez Chiapas,Díaz Núñez, J J; Universidad Autónoma de Ciudad Juárez Chihuahua,Taracena Sanz, L F; Instituto Tecnológico de Querétaro, Querétaro
Volatile Organic Compound Emissions from Light-Duty Vehicles During Cold-Starts,Emisiones de compuestos orgánicos volátiles durante arranques en frío de automóviles ligeros por Mendoza Domínguez, A; Tecnológico de Monterrey, Campus Monterrey, Nuevo León, México,León Romero, M A; Tecnológico de Monterrey, Campus Monterrey, Nuevo León, México,Caballero Mata, P
Matrix Formulation of Foundations for Vibrating Machinery in Frequency Domain,Formulación matricial de cimentaciones para maquinaria vibratoria en el dominio de la frecuencia por Carbajal Romero, M F; Instituto Politécnico Nacional. México DF,Rodríguez Castellanos, A; Instituto Mexicano del Petróleo. México DF,Rodríguez Sánchez, J E; Instituto Mexicano del Petróleo. México DF,Flores Méndez, E; IPN
Hydrogen Sorption Properties of the Intermetallic Mg2Ni Obtained by Using a Simoloyer Ball Milling,Propiedades de ab-desorción de hidrógeno del intermetálico Mg2Ni obtenido empleando un molino de bolas Simoloyer por Martínez Franco, E; IPN,Klassen, T; GKSS, Research Center Geesthacht, Germany,Jaramillo Vigueras, D; IPN,Bormann, R; GKSS, Research Center Geesthacht, Germany
Numerical Approach to an Outflow Hydrograph of a Dambreak,Estimación numérica del hidrograma de salida de una presa debido a su ruptura por Fuentes Mariles, O A; Universidad Nacional Autónoma de México,Arganis Juárez, M L; UNAM,De Luna Cruz, F; UNAM,Franco, V; UNAM
Electrical Parameters Extraction of CMOS Floating-Gate Inverters,Extracción de parámetros eléctricos de inversores CMOS de compuerta flotante por Molinar Solís, J E; Universidad Autónoma del Estado de México,Ponce Ponce, V H; IPN,García Lozano, R Z; Universidad Autónoma del Estado de México,Díaz Sanchez, A; Instituto Nacional de Astrofísica, Óptica y Electrónica INAOE,Rocha Pérez, j M; Instituto Nacional de Astrofísica, Óptica y Electrónica INAOE
Back Work Ratio of Brayton Cycle,La relación de trabajo de retroceso de un ciclo Brayton por Malaver de la Fuente, M; Universidad Marítima del Caribe, Venezuela
Active Rectifier with Extended Functions: An Option to Voltage Sags Ride Through and Power Quality Improvement,Rectificador activo con funciones ampliadas: una alternativa para la compensación de sags de voltaje y mejorar la calidad de la red eléctrica por Núñez Gutiérrez, C A; Universidad Autónoma de San Luis Potosí, SLP,Lira Pérez, J; Universidad Autónoma de San Luis Potosí, SLP,Pazos Flores, F; Universidad Autónoma de San Luis Potosí, SLP,Echavarría Solís, R; Universidad Politécnica de Victoria, Ciudad Victoria, Tamaulipas
10