Título: Alternating-frequency TENS effects on experimental pain in healthy human participants: a randomised placebo-controlled trial
Autores: Claydon, Leica S.
Chesterton, Linda S.
Barlas, Panos
Sim, Julius
Fecha: 2013-05-20
2013-05-20
2013-06
Publicador: Anglia Ruskin University
Fuente:
Tipo: Article
Tema: pain
randomised controlled trial
TENS
Descripción: BACKGROUND: : Transcutaneous electrical nerve stimulation (TENS) is a modality commonly used in pain management. OBJECTIVES: : This study investigated the hypoalgesic effects of alternating-frequency TENS (4 Hz for 3 s/110 Hz for 3 s) on pressure pain threshold (PPT). METHODS: : Two-hundred and eight healthy, pain-free volunteers (19 to 59 y old; 104 males, 104 females) were randomized to 8 groups: 6 active TENS groups, placebo, and control (n=26 per group). Parameter combinations were such that alternating-frequency TENS was combined with different levels of intensity "low" (strong but comfortable) or "high" (strong and uncomfortable but not painful). TENS was administered either at the forearm (segmental stimulation), at the ipsilateral leg (extrasegmental stimulation), or at both sites (dual-site stimulation) for 30 minutes and monitored for 30 further minutes. PPT measurements were taken bilaterally from the mid-point of first dorsal interosseous muscle, by an independent blinded rater, at baseline and at 6 subsequent 10-minute intervals. Square-root transformed data were analyzed using repeated measures analysis of covariance (baseline values and sex as covariates). RESULTS: : Alternating-frequency TENS groups did not achieve significant hypoalgesic effects compared with placebo or control (P>0.05). The largest increase in PPT (from baseline) was 76.6 kPa with low-intensity segmental alternating frequency TENS at the 20-minute stimulation time point. This change from baseline is below a difference of 100 kPa that is considered to be a clinically meaningful change in hypoalgesia. DISCUSSION: : The alternating-frequency setting does not result in large hypoalgesic effects such as those previously reported using fixed-frequency TENS.
Idioma: Inglés

Artículos similares:

Crowding under scotopic conditions por Simunovic, Matthew P.,Calver, Richard I.
Factors affecting group spread within wild mixed-species troops of saddleback and mustached tamarins por Smith, Andrew C.,Buchanan-Smith, Hannah M.,Surridge, Alison K.,Mundy, Nicholas I.
Development of a harmonised method for the profiling of amphetamines: I. Synthesis of standards and compilation of analytical data por Aalberg, Laura,Andersson, Kjell,Bertler, Christina,Borén, Hans,Cole, Michael D.,Dahlén, Johan,Finnon, Yvonne,Huizer, Henk,Jalava, Kaisa,Kaa, Elisabet,Lock, Eric,Lopes, Alvaro,Poortman-van der Meer, Anneke,Sippola, Erkki
Development of a harmonised method for the profiling of amphetamines: II. Stability of impurities in organic solvents por Aalberg, Laura,Andersson, Kjell,Bertler, Christina,Cole, Michael D.,Finnon, Yvonne,Huizer, Henk,Jalava, Kaisa,Kaa, Elisabet,Lock, Eric,Lopes, Alvaro,Poortman-van der Meer, Anneke,Sippola, Erkki,Dahlén, Johan
Peripheral refraction for distance and near vision in emmetropes and myopes por Calver, Richard I.,Radhakrishnan, Hema,Osuobeni, Ebi P.,O'Leary, Daniel J.
Development of a harmonised method for the profiling of amphetamines: III. Development of the gas chromatographic method por Andersson, Kjell,Jalava, Kaisa,Lock, Eric,Finnon, Yvonne,Huizer, Henk,Kaa, Elisabet,Lopes, Alvaro,Poortman-van der Meer, Anneke,Cole, Michael D.,Dahlén, Johan,Sippola, Erkki
Effect of positive and negative defocus on contrast sensitivity in myopes and non-myopes por Radhakrishnan, Hema,Pardhan, Shahina,Calver, Richard I.,O'Leary, Daniel J.
10 
Development of a harmonised method for the profiling of amphetamines: IV. Optimisation of sample preparation por Andersson, Kjell,Jalava, Kaisa,Lock, Eric,Huizer, Henk,Kaa, Elisabet,Lopes, Alvaro,Poortman-van der Meer, Anneke,Cole, Michael D.,Dahlén, Johan,Sippola, Erkki