Título: Evaluation of the spontaneous breathing trial in burn intensive care patients
Autores: Smailes, Sarah T.
Martin, Rebecca V.
McVicar, Andrew J.
Fecha: 2011-09-22
2011-09-22
2009-08
Publicador: Anglia Ruskin University
Fuente:
Tipo: Article
Tema: ventilation
extubation
spontaneous breathing trial
Descripción: BACKGROUND: The extubation failure rate in our burn patients is 30%. OBJECTIVE: To evaluate the influence of the 30 min spontaneous breathing trial on extubation outcome in burn patients. METHODS: A prospective, observational study in a burn intensive care unit. All adult patients requiring mechanical ventilation for >24h and meeting the inclusion criteria underwent a 30 min spontaneous breathing trial (SBT). Extubation was undertaken after a successful SBT. RESULTS: Of 49 planned extubations, 9 failed (18%), much lower than the 30% extubation failure rate identified prior to the implementation of the SBT. The duration of ventilation was significantly shorter (p=0.04) in the patients who passed a SBT and those who failed extubation were significantly older (p=0.003). The logistic regression analysis identified that age independently predicted extubation outcome. Patients who failed extubation, after a successful SBT, had a significantly longer duration of ventilation (p=0.0001) and ITU length of stay (p=0.001). CONCLUSIONS: The incidence of extubation failure was much lower and the duration of ventilation significantly shorter in patients who were extubated after a successful SBT. These findings support the use of the SBT in burn patients. Age independently predicts extubation outcome in burn patients who have passed a SBT.
Idioma: Inglés

Artículos similares:

Crowding under scotopic conditions por Simunovic, Matthew P.,Calver, Richard I.
Factors affecting group spread within wild mixed-species troops of saddleback and mustached tamarins por Smith, Andrew C.,Buchanan-Smith, Hannah M.,Surridge, Alison K.,Mundy, Nicholas I.
Development of a harmonised method for the profiling of amphetamines: I. Synthesis of standards and compilation of analytical data por Aalberg, Laura,Andersson, Kjell,Bertler, Christina,Borén, Hans,Cole, Michael D.,Dahlén, Johan,Finnon, Yvonne,Huizer, Henk,Jalava, Kaisa,Kaa, Elisabet,Lock, Eric,Lopes, Alvaro,Poortman-van der Meer, Anneke,Sippola, Erkki
Development of a harmonised method for the profiling of amphetamines: II. Stability of impurities in organic solvents por Aalberg, Laura,Andersson, Kjell,Bertler, Christina,Cole, Michael D.,Finnon, Yvonne,Huizer, Henk,Jalava, Kaisa,Kaa, Elisabet,Lock, Eric,Lopes, Alvaro,Poortman-van der Meer, Anneke,Sippola, Erkki,Dahlén, Johan
Peripheral refraction for distance and near vision in emmetropes and myopes por Calver, Richard I.,Radhakrishnan, Hema,Osuobeni, Ebi P.,O'Leary, Daniel J.
Development of a harmonised method for the profiling of amphetamines: III. Development of the gas chromatographic method por Andersson, Kjell,Jalava, Kaisa,Lock, Eric,Finnon, Yvonne,Huizer, Henk,Kaa, Elisabet,Lopes, Alvaro,Poortman-van der Meer, Anneke,Cole, Michael D.,Dahlén, Johan,Sippola, Erkki
Effect of positive and negative defocus on contrast sensitivity in myopes and non-myopes por Radhakrishnan, Hema,Pardhan, Shahina,Calver, Richard I.,O'Leary, Daniel J.
10 