Título: TELLURIC, SELF-POTENTIAL, AND SURFACE TEMPERATURE PROFILES ON LOS HUMEROS CALDERA
TELLURIC, SELF-POTENTIAL, AND SURFACE TEMPERATURE PROFILES ON LOS HUMEROS CALDERA
Autores: ALVAREZ, ROMÁN
Fecha: 2012-11-09
Publicador: Revistas UNAM
Fuente:
Tipo:

Tema: No aplica
Descripción: Two geophysical lines of 16.5 and 17 km in length have been surveyed in Los Humeros Caldera, in central-eastern Mexico, in order to delineate preliminary areas of geothermal interest. The E-field ratio telluric method, which consist of collinear dipoles and measurements at frequencies of .05% and 8 Hz, was used as reconnaissance tool to get an idea of the relative changes in electrical conductivity across the caldera; self potential and surface temperature data were also collected along the lines. Tellurics suggests sharp conductivity contrast on the west side of both lines and at both frequencies; in addition, the northern line appears to define quite well the collapse portion of the caldera along the profile, the topography of which is oblitarated by pyroclastics. Telluric and gravity data agree quite well in delineating the major structural features. Self-potential responses show that the western caldera rim is approximately 800 mV above the electric potential of the eastern rim. The average surface temperatures (i.e., 0.5 to 1 m depth) on the western caldera portion are from 3° to 6°C above the temperatures on the eastern portion. On the basis of this evidence the western flank of the caldera is proposed as the primary exploration target for geothermal purposes.
Se hicieron levantamientos geofísicos en dos líneas (16.5 y 17 km) de la caldera de Los Humeros, la cual se encuentra situada en la parte centro-oriental de México, con el propósito de delinear preliminarmente áreas de interés geotérmico. El método telúrico de cociente de campo eléctrico E, que consiste en dipolos colineales y medidas a frecuencias .05 y 8 Hz, se usó como método de reconocimiento para tener una idea de los cambios relativos en conductividad eléctrica a través de la caldera; se hicieron asimismo mediciones de autopotencial y temperatura superficial a lo largo de dichas líneas. Las respuestas telúricas sugieren marcados contrastes de conductividad en la parte occidental de ambas líneas y en ambas frecuencias; además, la línea más al norte parece definir con gran exactitud la porción colapsada (que está cubierta de piroclásticos) de la caldera a lo largo del perfil. Los datos telúricos y gravimétricos coinciden muy bien en delinear los rasgos estructurales más importantes de la caldera. El autopotencial muestra que el borde occidental de la caldera está aproximadamente 800 mV más alto que el potencial del borde oriental. Las temperaturas superficiales (i.e., 0.5 a 1 m de profundidad) en la parte occidental de la caldera están de 3° a 6°C más elevadas que las temperaturas en el lado oriental. Con base en estas evidencias proponemos que el flanco occidental de la caldera es un blanco primario de exploración para propósitos geotérmicos.
Idioma: No aplica

Artículos similares:

Ordered Hunt Schemes for Overlaid CDMA Cellular Systems,Esquemas de ordenamiento en sistemas celulares sobrepuestos CDMA por Castañeda Camacho, J; Benemérita Universidad Autónoma de Puebla, Puebla, México,Lara Rodríguez, D; IPN
Model for Adjustment of Aggregate Forecasts using Fuzzy Logic,Modelo para el ajuste de pronósticos agregados utilizando lógica difusa por Escobar Gómez, E N; Instituto Tecnológico de Tuxtla Gutiérrez Chiapas,Díaz Núñez, J J; Universidad Autónoma de Ciudad Juárez Chihuahua,Taracena Sanz, L F; Instituto Tecnológico de Querétaro, Querétaro
Volatile Organic Compound Emissions from Light-Duty Vehicles During Cold-Starts,Emisiones de compuestos orgánicos volátiles durante arranques en frío de automóviles ligeros por Mendoza Domínguez, A; Tecnológico de Monterrey, Campus Monterrey, Nuevo León, México,León Romero, M A; Tecnológico de Monterrey, Campus Monterrey, Nuevo León, México,Caballero Mata, P
Matrix Formulation of Foundations for Vibrating Machinery in Frequency Domain,Formulación matricial de cimentaciones para maquinaria vibratoria en el dominio de la frecuencia por Carbajal Romero, M F; Instituto Politécnico Nacional. México DF,Rodríguez Castellanos, A; Instituto Mexicano del Petróleo. México DF,Rodríguez Sánchez, J E; Instituto Mexicano del Petróleo. México DF,Flores Méndez, E; IPN
Hydrogen Sorption Properties of the Intermetallic Mg2Ni Obtained by Using a Simoloyer Ball Milling,Propiedades de ab-desorción de hidrógeno del intermetálico Mg2Ni obtenido empleando un molino de bolas Simoloyer por Martínez Franco, E; IPN,Klassen, T; GKSS, Research Center Geesthacht, Germany,Jaramillo Vigueras, D; IPN,Bormann, R; GKSS, Research Center Geesthacht, Germany
Numerical Approach to an Outflow Hydrograph of a Dambreak,Estimación numérica del hidrograma de salida de una presa debido a su ruptura por Fuentes Mariles, O A; Universidad Nacional Autónoma de México,Arganis Juárez, M L; UNAM,De Luna Cruz, F; UNAM,Franco, V; UNAM
Electrical Parameters Extraction of CMOS Floating-Gate Inverters,Extracción de parámetros eléctricos de inversores CMOS de compuerta flotante por Molinar Solís, J E; Universidad Autónoma del Estado de México,Ponce Ponce, V H; IPN,García Lozano, R Z; Universidad Autónoma del Estado de México,Díaz Sanchez, A; Instituto Nacional de Astrofísica, Óptica y Electrónica INAOE,Rocha Pérez, j M; Instituto Nacional de Astrofísica, Óptica y Electrónica INAOE
Back Work Ratio of Brayton Cycle,La relación de trabajo de retroceso de un ciclo Brayton por Malaver de la Fuente, M; Universidad Marítima del Caribe, Venezuela
Active Rectifier with Extended Functions: An Option to Voltage Sags Ride Through and Power Quality Improvement,Rectificador activo con funciones ampliadas: una alternativa para la compensación de sags de voltaje y mejorar la calidad de la red eléctrica por Núñez Gutiérrez, C A; Universidad Autónoma de San Luis Potosí, SLP,Lira Pérez, J; Universidad Autónoma de San Luis Potosí, SLP,Pazos Flores, F; Universidad Autónoma de San Luis Potosí, SLP,Echavarría Solís, R; Universidad Politécnica de Victoria, Ciudad Victoria, Tamaulipas
10