Título: Fluxes of sensible heat and momentum in the surface layer estimated from the profile measurements of wind and temperature at a tropical station
Fluxes of sensible heat and momentum in the surface layer estimated from the profile measurements of wind and temperature at a tropical station
Autores: JEGEDE, OLUWAGBEMIGA O.
LOFSTROM, PER
Fecha: 1969-12-31
Publicador: Revistas UNAM
Fuente:
Tipo:

Tema: No aplica
Descripción: In this study the surface layer fluxes for both the sensible heat and momentum have been estimated at a tropical location; Osu, Nigeria (7º26' N, 4º35' E), using profile measurements of mean wind and temperature realized within the pre-monsoon season (January - March). Due to the weak surface winds that commonly exist in the area (for the study period, U was 1.24 m.s-1) and strong insolation, the daytime SL was frequently found to be within the free convection regime. Typically in the daytime, the sensible heat flux H~200 W.m-2 and the friction velocity u* ~ 0.2 m.s-1. At nighttimes, the ground-based temperature inversion was very pronounced (>0.33ºC.m-1) and it is such that the intensity of the turbulence in the nocturnal SL was weaker, shallower, sporadic and unsustained (H~ -5.0 W.m-2; * < 0.2 m.s-1). The frequency distribution of these derived fluxes (and the mean variables) for the observation period is also discussed.
EN ESTE ESTUDIO HAN SIDO ESTIMADOS LOS FLUJOS EN LA CAPA SUPERFICIAL PARA LA CANTIDAD DE MOVIMIENTO COMO PARA EL CALOR SENSIBLE EN UN LUGAR TROPICAL; OSU, NIGERIA (7°26'N, 4°35'E), USANDO MEDICIONES DE PERFILES DE VIENTO MEDIO Y TEMPERATURA, LLEVADAS A CABO EN LA ESTACIÓN ANTERIOR AL MONZÓN (ENERO-MARZO). DEBIDO A LOS VIENTOS DÉBILES DE SUPERFICIE QUE GENERALMENTE EXISTEN EN EL ÁREA (PARA EL PERIODO DE ESTUDIO ERA 1.24 M.S-1) Y LA FUERTE INSOLACIÓN, EL SL DEL TIEMPO DIURNO SE ENCONTRÓ CON FRECUENCIA QUE ESTABA DENTRO DEL RÉGIMEN DE CONVECCIÓN LIBRE. TÍPICAMENTE EN EL TIEMPO DIURNO EL FLUJO DE CALOR SENSIBLE ERA H~200 W.M-2 Y LA VELOCIDAD DE FRICCIÓN 0.2M.S-1. EN EL TIEMPO NOCTURNO LA INVERSIÓN DE TEMPERATURA CON BASE EN LA SUPERFICIE ERA MUY PRONUNCIADA (>0.33°C. M-1) EN TAL FORMA QUE LA INTENSIDAD DE LA TURBULENCIA EN EL SL NOCTURNO ERA MAS DÉBIL, MENOS ALTA, ESPORÁDICA Y MENOS PROLONGADA (H~-5.0W.M-2,
Idioma: Inglés

Artículos similares:

Ordered Hunt Schemes for Overlaid CDMA Cellular Systems,Esquemas de ordenamiento en sistemas celulares sobrepuestos CDMA por Castañeda Camacho, J; Benemérita Universidad Autónoma de Puebla, Puebla, México,Lara Rodríguez, D; IPN
Model for Adjustment of Aggregate Forecasts using Fuzzy Logic,Modelo para el ajuste de pronósticos agregados utilizando lógica difusa por Escobar Gómez, E N; Instituto Tecnológico de Tuxtla Gutiérrez Chiapas,Díaz Núñez, J J; Universidad Autónoma de Ciudad Juárez Chihuahua,Taracena Sanz, L F; Instituto Tecnológico de Querétaro, Querétaro
Volatile Organic Compound Emissions from Light-Duty Vehicles During Cold-Starts,Emisiones de compuestos orgánicos volátiles durante arranques en frío de automóviles ligeros por Mendoza Domínguez, A; Tecnológico de Monterrey, Campus Monterrey, Nuevo León, México,León Romero, M A; Tecnológico de Monterrey, Campus Monterrey, Nuevo León, México,Caballero Mata, P
Matrix Formulation of Foundations for Vibrating Machinery in Frequency Domain,Formulación matricial de cimentaciones para maquinaria vibratoria en el dominio de la frecuencia por Carbajal Romero, M F; Instituto Politécnico Nacional. México DF,Rodríguez Castellanos, A; Instituto Mexicano del Petróleo. México DF,Rodríguez Sánchez, J E; Instituto Mexicano del Petróleo. México DF,Flores Méndez, E; IPN
Hydrogen Sorption Properties of the Intermetallic Mg2Ni Obtained by Using a Simoloyer Ball Milling,Propiedades de ab-desorción de hidrógeno del intermetálico Mg2Ni obtenido empleando un molino de bolas Simoloyer por Martínez Franco, E; IPN,Klassen, T; GKSS, Research Center Geesthacht, Germany,Jaramillo Vigueras, D; IPN,Bormann, R; GKSS, Research Center Geesthacht, Germany
Numerical Approach to an Outflow Hydrograph of a Dambreak,Estimación numérica del hidrograma de salida de una presa debido a su ruptura por Fuentes Mariles, O A; Universidad Nacional Autónoma de México,Arganis Juárez, M L; UNAM,De Luna Cruz, F; UNAM,Franco, V; UNAM
Electrical Parameters Extraction of CMOS Floating-Gate Inverters,Extracción de parámetros eléctricos de inversores CMOS de compuerta flotante por Molinar Solís, J E; Universidad Autónoma del Estado de México,Ponce Ponce, V H; IPN,García Lozano, R Z; Universidad Autónoma del Estado de México,Díaz Sanchez, A; Instituto Nacional de Astrofísica, Óptica y Electrónica INAOE,Rocha Pérez, j M; Instituto Nacional de Astrofísica, Óptica y Electrónica INAOE
Back Work Ratio of Brayton Cycle,La relación de trabajo de retroceso de un ciclo Brayton por Malaver de la Fuente, M; Universidad Marítima del Caribe, Venezuela
Active Rectifier with Extended Functions: An Option to Voltage Sags Ride Through and Power Quality Improvement,Rectificador activo con funciones ampliadas: una alternativa para la compensación de sags de voltaje y mejorar la calidad de la red eléctrica por Núñez Gutiérrez, C A; Universidad Autónoma de San Luis Potosí, SLP,Lira Pérez, J; Universidad Autónoma de San Luis Potosí, SLP,Pazos Flores, F; Universidad Autónoma de San Luis Potosí, SLP,Echavarría Solís, R; Universidad Politécnica de Victoria, Ciudad Victoria, Tamaulipas
10