Título: Utilização do pico de fluxo expiratório no manejo da asma aguda em serviços de emergência da cidade de Campo Grande-MS
Use of peak flow in the management of acute asthma in emergency services from the city of Campo Grande-MS
Autores: Neto, Sami Saher; Hospital Adventista do Pênfigo
Miranda, Aldo Silva de; Universidade Católica Dom Bosco
Santos, Mara Lisiane M.; Universidade Católica Dom Bosco
Tavares, Luciana Venhofen Martinelli; Universidade Federal de Mato Grosso do Sul
Freitas, Patrícia Jovenilia de; Hospital Adventista do Pênfigo
Fecha: 2010-09-20
Publicador: Assobrafir Ciência
Fuente:
Tipo: info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Avaliado por pares


Tema:
Pico de fluxo expiratório, Asma, Crise asmática.

Peak flow, Asthma, Breathlessness.
Descripción: Objetivos: Analisar a utilização e o conhecimento dos profissionais de saúde nos setores de emergência da rede pública da cidade de Campo Grande, capital do estado do Mato Grosso do Sul, quanto à utilização da medida de pico de fluxo expiratório (PFE) no manejo da asma aguda. Métodos: Foram analisados 133 questionários respondidos por profissionais da saúde: 72 em hospitais públicos e 61 em centros regionais de saúde: médicos, fisioterapeutas, enfermeiros, técnicos e auxiliares de enfermagem que realizam o atendimento de emergência a pacientes em crise asmática nos serviços da rede pública de saúde. O questionário abordou questões referentes ao conhecimento dos profissionais sobre o aparelho de medida do pico de fluxo expiratório, sua utilização no manejo da asma aguda, bem como o conhecimento das diretrizes que o recomendam. Resultados: Quanto ao conhecimento sobre o aparelho de medida do pico de fluxo expiratório nos centros regionais de saúde, 88,52% (n=54) não têm conhecimento sobre o equipamento, apenas 11,48% (n=7) relataram conhecer o equipamento. Nos hospitais públicos, 70,83% (n=51) não tinham conhecimento sobre o equipamento para a medida do pico de fluxo expiratório e 29,17% (n=21) relataram ter conhecimento sobre o equipamento. Em relação à disponibilidade deste equipamento, 100% (n=133) dos entrevistados relataram que o equipamento não é disponibilizado em seu serviço. Quanto ao conhecimento sobre as diretrizes que recomendam a utilização da medida do PFE no manejo da asma, dos entrevistados nos centros regionais de saúde (CRS), 96,72% (n=59) não tinham conhecimento a respeito destas diretrizes enquanto que somente 3,28% (n=2) tinham conhecimento sobre elas. Já nos hospitais públicos, dos entrevistados, 76,39% (n=55) não tinham conhecimento a respeito destas diretrizes enquanto que somente 23,61% (n=17) tinham conhecimento sobre elas. Conclusão: Fica em evidência a falta de conhecimento tanto do aparelho de medida do pico de fluxo expiratório quanto das diretrizes que recomendam sua utilização no manejo da asma aguda por parte dos profissionais de saúde, indisponibilidade deste equipamento e conseqüentemente a não utilização deste equipamento no manejo da asma aguda nos setores de emergência da rede pública de saúde, da cidade de Campo Grande-MS.
Objectives: To analyze the use and knowledge of health professionals in various fields of emergency public network of the city of Campo Grande, MS, on the utilization of the measure of peak expiratory flow in the management of acute asthma. Methods: A total of 133 questionnaires were answered by health professionals, among them 72 professionals in public hospitals and 61 in regional health center. They were medical doctors, physical therapists, nurses, technicians and nursing assistants, who held the emergency care to patients in asthmatic crisis in the services of the public health, and were present at the time of the visit of the researchers. The questionnaire addressed issues relating to the attention of professionals about the measurement of peak expiratory flow, its use in the management of acute asthma, as well as knowledge of the recommendation guidelines. Results: On the knowledge about measurement of peak expiratory flow in regional centers of health 88.52% (n = 54) had no knowledge of the equipment, only 11.48% (n = 7) reported knowing the equipment. In public hospitals 70.83% (n = 51) had no knowledge of the equipment for the measurement of peak expiratory flow and 29.17% (n = 21) reported having knowledge about the equipment. Regarding the availability of this equipment 100% (n = 133) of those interviewed reported that the equipment was not available in their service. Concerning the knowledge of the guidelines which recommend that the management of acute asthma is based on the measurement of peak expiratory flow, the interviewees in regional centers for health (CRS) 96.72% (n = 59) had no knowledge about these guidelines whereas only 3.28 % (n = 2) had knowledge of them. In public hospitals, 76.39% (n = 55) of the interviewees had no knowledge about these guidelines while only 23.61% (n = 17) had knowledge of them. Conclusion: Lack of knowledge was observed both for the measurement of peak expiratory flow as for the guidelines which recommend its use in the management of acute asthma by health professionals responsible for emergency care in sectors of the public health in the city of Campo Grande-MS, Brazil.
Idioma: Portugués

Artículos similares:

Falha de extubação orotraqueal após sucesso no teste de respiração espontânea por da Silva, Renata Cardoso; Hospital Santo Antônio-Obras Sociais Irmã Dulce, Salvador-Bahia.,Alvarez, Renata Freres; Fisioterapeuta assistencial do hospital Espanhol, Salvador-Bahia.,de Barros, Idiel Araújo; Hospital Santo Antônio-Obras Sociais Irmã Dulce, Salvador-Bahia.,Santos, Daniel Reis; Hospital Santo Antônio-Obras Sociais Irmã Dulce, Salvador-Bahia.,Farias, Simone Vilas; Hospital Santo Antônio-Obras Sociais Irmã Dulce, Salvador-Bahia.,Duarte, Marta Gomes; Hospital Santo Antônio-Obras Sociais Irmã Dulce, Salvador-Bahia.,Pimentel, Zaira Lima; Hospital Santo Antônio-Obras Sociais Irmã Dulce, Salvador-Bahia.,Martinez, Bruno Prata; Hospital Santo Antônio- Obras Sociais Irmã Dulce, Salvador- Bahia.
Comportamento dos valores da pressão inspiratória máxima e do índice de respiração rápida superficial durante o teste de respiração espontânea por França, Eduardo Eriko Tenório de; Hospital Agamenon Magalhães (HAM) e Universidade Católica de Pernambuco (UNICAP),Melo, Priscilla Gonçalves; UNICAP,Costa, Maria Cecília Cedrim; UNICAP,Ramos, Francimar Ferrari; Faculdade Integrada do Recife,Júnior, Marco Aurélio Valois Correa; Universidade de Pernambuco,Castro, Célia Maria Barbosa de Andrade; Universidade Federal de Pernambuco,Andrade, Maria Amparo; Universidade Federal de Pernambuco,Dias de Andrade, Flávio Maciel; UNICAP,Ribeiro, Luana Carneiro; Hospital Agamenon Magalhães,Costa, Eduarda Lubambo; Hospital Agamenon Magalhaes,Souza, Carolina Sales de; Hospital Agamenon Magalhaes,Melo, Mateus Parrois Torres de; UNICAP
Comparação entre o trabalho desenvolvido e a distância percorrida no teste de caminhada de seis minutos para avaliação da capacidade funcional de pneumopatas crônicos por Figueiredo, Pedro Henrique Scheidt,Costa, Denílson Otavio da,Afeitos, Thiago Diniz,Reis, Wagner Júnio Oliveiras
Passos dados, medidas antropométricas e atividade física em jovens: há associação? por Macedo, Luciana Bilitário; Escola Bahiana de Medicina e Saúde Pública (BAHIANA) Universidade do Estado da Bahia (UNEB),Sá, Cloud Kennedy Couto; Escola Bahiana de Medicina e Saúde Pública (BAHIANA),Ladeia, Ana Marice Teixeira; Escola Bahiana de Medicina e Saúde Pública (BAHIANA)
Comparison of physical activity level in daily life between patients with Chronic Obstructive Pulmonary Disease with and without professional activity,Comparação do nível de atividade física na vida diária entre pacientes portadores da Doença Pulmonar Obstrutiva Crônica (DPOC) com e sem atividade profissional por Sant’Anna, Thaís Jordão Perez; Universidade Estadual de Londrina,Fontana, Andréa Daiane; Universidade Estadual de Londrina,Oliveira, Natália Helena de; Universidade Estadual de Londrina,Probst, Vanessa Suziani; Universidade Estadual de Londrina,Brunetto, Antonio Fernando; Universidade Estadual de Londrina,Pitta, Fábio de Oliveira; Universidade Estadual de Londrina
O desenvolvimento técnico científico aliado ao fortalecimento político como base para consolidação das nossas especialidades por de Andrade, Flávio Maciel Dias; Editor Chefe ASSOBRAFIR Ciência,Martins, Jocimar Avelar
ASSOBRAFIR Ciência - v.3, n.4 (2012) por Guimaraes, Fernando; Editor Chefe ASSOBRAFIR Ciência
10 
Análise comparativa entre dois métodos de monitorização do volume minuto em pacientes coronariopatas em um hospital de referência em cardiologia. por Silva, Julianna Falcão,Silva, Diego Henrique Barreto da,Coelho, Gabriela Rodrigues de Albuquerque,Souza, Ana Georgia Lima de,Miranda, Juliana Meirinhos,Silva, Talita Miranda,Silva, Noberto Fernandes da,Pereira Junior, Clodoval de Barros