Título: Eficiência de um conjunto fotovoltaico em condições reais de trabalho na região de Cascavel - DOI: 10.4025/actascitechnol.v30i2.5496
Efficiency of the photovoltaic systems under real work conditions on region of Cascavel - DOI: 10.4025/actascitechnol.v30i2.5496
Autores: Gnoatto, Estor; UTFPR
Dallacort, Rivanildo; UNEMAT
Prandini Ricieri, Reinaldo; UNIOESTE
de Lima Silva, Suedemio; UNIOESTE
Ferruzi, Yuri; UNIOESTE
Fecha: 2008-10-20
Publicador: Acta Scientiarum. Techonology
Fuente:
Tipo:



Tema: 1.05.00.00-6 Física
energia solar; sistemas fotovoltaicos; recursos renováveis.


solar energy; photovoltaic systems; renewable resources

Descripción: No presente trabalho, foi desenvolvido um estudo sobre um sistema fotovoltaico autônomo, com armazenamento de energia, instalado na Estação Experimental Agrometeorológica da Universidade Estadual do Oeste do Paraná, Campus Cascavel, a uma Latitude 24°59' Sul, Longitude de 53°26' Oeste, com altitude de 682 m, em condições reais de campo, durante o ano de 2002. Foi avaliada a eficiência dos painéis fotovoltaicos em condições reais de campo, sua curva característica foi determinada utilizando, na aquisição de dados, um micrologger da Campbell Scientific-Inc, modelo CR10X, programado para realizar uma leitura por segundo de cada canal e armazenar a média aritmética de 5 minutos dos dados das componentes de radiação solar global no plano horizontal e global na incidência do painel; temperatura ambiente e temperatura de operação do painel; tensão e corrente do sistema fotovoltaico. Os resultados mostram que a eficiência média mensal registrou valores na faixa de 8,65 a 9,17%, com uma média de 8,84%, com variação percentual entre o índice máximo e mínimo de 5,67%. Pode, assim, representar fornecimento médio mensal de energia de 5,57 kWh por painel.
The purpose of the present work was to develop a study of an autonomous photovoltaic system, with energy storage, installed at the Experimental Agrometeorological Station of the Universidade Estadual do Oeste do Paraná, Cascavel Campus, located at 24º59’S 53º26’W, 682 meters of altitude, under real field conditions, during the year of 2002. The efficiency of the photovoltaic modules was evaluated under real field conditions and its characteristic linear fit was determined. A Campbell Scientific CR10X micrologger was used to acquire data, programmed to conduct one reading per second from each channel and store the five-minute arithmetic data average from the readings of the incidence of global direct solar radiation (horizontal and global) on the panel, as well as area temperature, panel operational temperature, photovoltaic system tension and current. The results show that average monthly efficiency registered values in the range from 8.65 to 9.17%, with and average of 8.84%, and variation of 5.67%. Therefore, this array can supply a monthly average of 5.57 kWh per panel.
Idioma: Portugués

Artículos similares:

Remoção da prata em efluentes radiográficos - DOI: 10.4025/actascitechnol.v29i1.83,Silver removal in radiographic wastewaters por Bortoletto, Edmilson Cesar; UEM,Igarashi-Mafra, Luciana; UEM,Sorbo, Amanda Cristina Alfredo Contrucci; UEM,Galliani, Naiara Aguiar; UEM,Barros, Maria Angélica Simões Dornellas de; UEM,Tavares, Celia Regina Granhen; Engenharia Química - UEM
Oxidação seletiva de benzeno a fenol utilizando catalisadores metaloporfirínicos - DOI: 10.4025/actascitechnol.v29i1.84,Selective oxidation of benzene to phenol with metaloporphyrins catalysts por Olsen, Mara Heloisa Neves; UEM,Andrade, Liliane Pires; UEM,Salomão, Gisele Cantalice; UFRJ,Fernandes, Christiane; UENF,Horn Júnior, Adolfo; UENF,Cardozo-Filho, Lúcio; UEM,Antunes, Octavio Augusto Ceva; UFRJ
Simulação e análise de um sistema industrial de colunas de destilação de etanol - DOI: 10.4025/actascitechnol.v29i1.81,Simulation and analysis of an industrial system of columns for ethanol distillation por Marquini, Maria Fatima; UEM,Mariani, Douglas Castilho; UEM,Meirelles, Antonio José de Almeida; UEM,Santos, Onélia Aparecida Andreo dos; UEM,Jorge, Luiz Mario de Matos; UEM