Título: Optimal Placement of Custom Power Devices in Power System Network to Mitigate Voltage Sag under Faults
Autores: Tanti, D.K.; Department of Electrical Engineering, Birsa Institute of Technology
Verma, M.K.; Department of Electrical Engineering, Institute of Technology, Banaras Hindu University
Singh, Brijesh; Department of Electrical Engineering, Institute of Technology, Banaras Hindu University
Mehrotra, O.N.; Department of Electrical Engineering, Birsa Institute of Technology
Fecha: 2012-06-25
Publicador: International journal of power electronics and drive systems
Fuente:
Tipo: info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Tema: No aplica
Descripción: Voltage sag has been considered to be a serious power quality problem faced by many utilities. Placement of custom power devices may prove to be an effective remedy for solving power quality problems. In this paper, an Artificial Neural Network (ANN) based approach for optimal placement of Distribution Static Synchronous Compensator (DSTATCOM), Dynamic Voltage Restorer (DVR) and Unified Power Quality Conditioner (UPQC) in a power system network has been considered to mitigate voltage sag under faults. Voltage sag under different type of short circuits has been estimated using MATLAB/SIMULINK software. Optimal location of custom power devices has been obtained using a feed forward neural network trained by post-fault voltage magnitude of three phases at different buses. A comparative performance of DSTATCOM, DVR and UPQC in voltage sag mitigation has been studied to select most effective controller out of three controllers for the system. Case studies have been performed on IEEE 14-bus system. The effectiveness of proposed approach of placement of custom power devices has been established on the test system considered.
Idioma: Inglés

Artículos similares:

Simulation of a Transient Fault Controller for a Grid Connected Wind Farm with Different Types of Generators por Abdel-Mageed, Helmy Mohammed; Helwan University,Sharaf, S.M.,El_masry, S.M.,El_harony, M.; Helwan University
Unified Power Quality Conditioner for voltage sag and harmonic mitigation of nonlinear loads por Latha, Y. Kusuma; Lakireddy Balireddy College of Engineering (Autonomous),Saibabu, Ch.; University College of Engineering (Autonomous),Obulesu, Y P; Lakireddy Balireddy College of Engineering(Autonomous)
Dynamic Testing & Simulation of 4 KW (5.5 Hp) Switched Reluctance Motor using PSpice por Autee, Rajesh Murlidharrao; Marathwada Shikshan Prasarak Mandal's Deogiri Technical Campus for Engineeing & Mgt Studies, Aurangabad. Aff-Dr. B.A.M.University, Aurangabad-India.
A Novel method of Starting Induction Motor - A Comparative Study por Chakrasali, R L; SDM College of Engg.&Tech., Dharwad,Sheelavant, V.R.,Nagaraja, H.N.
10 
Regeneration of ZVS converter with Resonant inductor por Prasad, J.Sivavara,Babu, Ch.Sai,Obelesh, Y.P.