Título: Seasonal and spatial variation of atmospheric particulate matter in a developing megacity, the Greater Cairo, Egypt
Seasonal and spatial variation of atmospheric particulate matter in a developing megacity, the Greater Cairo, Egypt
Autores: ZAKEY, A. S.
ABDEL WAHAB, M.
PETTERSSON, J. B. C.
GATARI, M. J.
HALLQUIST, M.
Fecha: 1969-12-31
Publicador: Revistas UNAM
Fuente:
Tipo:

Tema: Megacity, lead, air quality, air pollution, dust storm, PM10, PM2.5
;MEGACITY; LEAD; AIR QUALITY; AIR POLLUTION; DUST STORM; PM10; PM25
Descripción: As an example of a developing megacity the Greater Cairo (GC) area in Egypt has been evaluated with respect to atmospheric particulate matter (PM) and lead (Pb). Particulate matter was collected during 2001-2002 in the two size fractions PM2.5 and PM10 at 17 sites representing different activities (industrial, urban, residential and background condition). The PM concentrations were generally high, with yearly average PM2.5 and PM10 values of 85 ± 12 and 170 ± 25 μg/m-3, respectively. On an annual scale, the high PM levels were due to many sources that included traffic, waste burning and wind blown dust particles emitted from the desert outside GC and the Moqattam hill inside GC. On a seasonal scale, the PM concentrations were highest in the industrial sector during spring, the dusty season, due to the combined effect of dust storm events and anthropogenic emissions over GC. The lowest seasonal concentrations were recorded in the summer season at the background sites. There was a marked increase in PM levels during the period October to December due to burning of waste from harvested rice in the agriculture area in the Nile Delta (north of Cairo). The highest PM2.5/PM10 ratio was recorded in the urban sector (0.59) while the lowest ratio was recorded in the residential sector (0.32). The PM2.5 and PM10 samples were also analyzed for Pb in order to address the influence of different emission sources. The monthly average concentrations of Pb in both PM2.5 (Pb2.5) and PM10 (Pb10) varied between 0.4 and 1.8 ± μg m-3 at the non industrial sites. The concentrations were significantly higher in the industrial areas, where concentration up to a maximum of 16 ± g m-3 could be observed. Both the high lead and PM concentrations measured are contributing to local environmental pollution. GC is subjected to high concentrations of particulates most of the year. There is no annual limit for PM10 concentrations in the Egyptian law of environment, but comparing to the 24 hour average, PM10 is representing health risks on the long-term that will give both regionally and globally environmental effects. High volume samplers measuring PM10 as daily average shows that the air quality limit value has been exceeded at sites Heliopolis (35), Maadi (6) and 6th October (13) during 60.47, 79.07, and 62.96% of the measuring period of 2001, and at Shoubra El-Kheima (20), El-Qolaly Sq (1), and Abbasiya (36) during 100.0, 91.7, and 89.8% of the measuring period of 2002. Thus, the evaluation of the data presented in this paper will serve as a basis for future regional and global modelling and source apportionment.
COMO EJEMPLO DE UNA MEGA CIUDAD EN DESARROLLO SE EVALUÓ EL ÁREA DEL GRAN CAIRO, EGIPTO (GC) EN RELACIÓN CON LAS PARTÍCULAS (PM) Y EL PLOMO (PB) ATMOSFÉRICOS. LAS PARTÍCULAS SE COLECTARON DURANTE 2001-2002 EN DOS TAMAÑOS DE FRACCIÓN, PM2.5 Y PM10 DE 17 SITIOS REPRESENTATIVOS DE DIFERENTES CARACTERÍSTICAS (INDUSTRIALES, URBANAS, RESIDENCIALES Y AMBIENTE NO ALTERADO). LAS CONCENTRACIONES DE PARTÍCULAS FUERON EN GENERAL ALTAS, CON PROMEDIOS ANUALES DE 85 ± 12 Å’G M-3 PARA PM2.5 Y DE 170 ± 25 PARA PM10. EN UNA ESCALA ANUAL, LOS NIVELES ELEVADOS DE PM SE DEBEN A VARIAS FUENTES QUE INCLUYEN EL TRÁFICO, LA INCINERACIÓN DE DESECHOS, PARTÍCULAS DE POLVO TRANSPORTADAS POR EL VIENTO DESDE EL DESIERTO FUERA DEL GC, Y DENTRO DEL GC DESDE LA COLINA MOQATTAM. EN UNA ESCALA ESTACIONAL, LAS CONCENTRACIONES DE PM SON MÁS ELEVADAS EN EL SECTOR INDUSTRIAL DURANTE LA PRIMAVERA, LA ESTACIÓN POLVOSA, DEBIDO AL EFECTO COMBINADO DE LAS TORMENTAS DE POLVO Y LAS EMISIONES ANTRÓPICAS EN EL GC. LAS CONCENTRACIONES ESTACIONALES MÁS BAJAS SE REGISTRARON EN EL VERANO EN LOS SITIOS NO ALTERADOS. HUBO UN INCREMENTO NOTABLE EN LOS NIVELES DE PM DURANTE EL PERIODO DE OCTUBRE A DICIEMBRE DEBIDO A LA INCINERACIÓN DE DESECHOS DE LAS COSECHAS DE ARROZ EN EL ÁREA DEL DELTA DEL NILO (AL NORTE DEL CAIRO). LA RELACIÓN PM2.5/PM10 MÁS ALTA (0.59) QUE SE REGISTRÓ CORRESPONDE AL SECTOR URBANO, MIENTRAS QUE LA MÁS BAJA (0.32) ES DEL SECTOR RESIDENCIAL. LAS MUESTRAS DE PM2.5 Y PM10 TAMBIÉN SE ANALIZARON PARA PB CON EL FIN DE DETERMINAR LA INFLUENCIA DE DIFERENTES FUENTES DE EMISIÓN. LAS CONCENTRACIONES PROMEDIO MENSUALES DE PB EN PM2.5 (PB2.5) Y PM10 (PB10) VARIARON ENTRE 0.4 Y 1.8 Å’G M-3 EN LOS SITIOS NO INDUSTRIALES. LAS CONCENTRACIONES FUERON SIGNIFICATIVAMENTE MAYORES EN LAS ÁREAS INDUSTRIALES, EN LAS QUE SE OBSERVÓ UN MÁXIMO DE 16 Å’G M-3. LAS CONCENTRACIONES ELEVADAS DE PB Y PM DETERMINADAS CONTRIBUYEN A LA CONTAMINACIÓN AMBIENTAL LOCAL. EL GC ESTÁ SUJETO A CONCENTRACIONES ELEVADAS DE PARTÍCULAS DURANTE TODO EL AÑO. NO HAY UN LÍMITE ANUAL PARA LAS CONCENTRACIONES DE PM10 EN LA LEY AMBIENTAL EGIPCIA, PERO AL COMPARARLAS CON LOS PROMEDIOS DE 24 H, LAS PM10 REPRESENTAN RIESGOS DE LARGO PLAZO A LA SALUD YA QUE TIENEN EFECTOS AMBIENTALES LOCALES Y REGIONALES. LOS MUESTREOS DE ALTO VOLUMEN DE PM10 CONSIDERADOS COMO PROMEDIOS DIARIOS MUESTRAN QUE LOS LÍMITES DE CALIDAD DEL AIRE SE EXCEDIERON 60.47, 79.07 Y 62.96 % EN LOS SITIOS HELIOPOLIS (35), MAADI (6) Y 6 DE OCTUBRE (13) DURANTE EL PERIODO DE MEDICIÓN DE 2001 Y 100, 91.7 Y 89.8 % EN SHOUBRA EL-KHEIMA (20), EL-QOLAY SQ (1) Y ABBASIYA (36) DURANTE EL PERIODO DE 2002. LA EVALUACIÓN DE LOS DATOS PRESENTADOS EN ESTE TRABAJO SERVIRÁ COMO BASE PARA FUTURAS MODELACIONES REGIONALES Y GLOBALES Y PARA LA CLASIFICACIÓN DE LAS FUENTES.
Idioma: Inglés

Artículos similares:

Ordered Hunt Schemes for Overlaid CDMA Cellular Systems,Esquemas de ordenamiento en sistemas celulares sobrepuestos CDMA por Castañeda Camacho, J; Benemérita Universidad Autónoma de Puebla, Puebla, México,Lara Rodríguez, D; IPN
Model for Adjustment of Aggregate Forecasts using Fuzzy Logic,Modelo para el ajuste de pronósticos agregados utilizando lógica difusa por Escobar Gómez, E N; Instituto Tecnológico de Tuxtla Gutiérrez Chiapas,Díaz Núñez, J J; Universidad Autónoma de Ciudad Juárez Chihuahua,Taracena Sanz, L F; Instituto Tecnológico de Querétaro, Querétaro
Volatile Organic Compound Emissions from Light-Duty Vehicles During Cold-Starts,Emisiones de compuestos orgánicos volátiles durante arranques en frío de automóviles ligeros por Mendoza Domínguez, A; Tecnológico de Monterrey, Campus Monterrey, Nuevo León, México,León Romero, M A; Tecnológico de Monterrey, Campus Monterrey, Nuevo León, México,Caballero Mata, P
Matrix Formulation of Foundations for Vibrating Machinery in Frequency Domain,Formulación matricial de cimentaciones para maquinaria vibratoria en el dominio de la frecuencia por Carbajal Romero, M F; Instituto Politécnico Nacional. México DF,Rodríguez Castellanos, A; Instituto Mexicano del Petróleo. México DF,Rodríguez Sánchez, J E; Instituto Mexicano del Petróleo. México DF,Flores Méndez, E; IPN
Hydrogen Sorption Properties of the Intermetallic Mg2Ni Obtained by Using a Simoloyer Ball Milling,Propiedades de ab-desorción de hidrógeno del intermetálico Mg2Ni obtenido empleando un molino de bolas Simoloyer por Martínez Franco, E; IPN,Klassen, T; GKSS, Research Center Geesthacht, Germany,Jaramillo Vigueras, D; IPN,Bormann, R; GKSS, Research Center Geesthacht, Germany
Numerical Approach to an Outflow Hydrograph of a Dambreak,Estimación numérica del hidrograma de salida de una presa debido a su ruptura por Fuentes Mariles, O A; Universidad Nacional Autónoma de México,Arganis Juárez, M L; UNAM,De Luna Cruz, F; UNAM,Franco, V; UNAM
Electrical Parameters Extraction of CMOS Floating-Gate Inverters,Extracción de parámetros eléctricos de inversores CMOS de compuerta flotante por Molinar Solís, J E; Universidad Autónoma del Estado de México,Ponce Ponce, V H; IPN,García Lozano, R Z; Universidad Autónoma del Estado de México,Díaz Sanchez, A; Instituto Nacional de Astrofísica, Óptica y Electrónica INAOE,Rocha Pérez, j M; Instituto Nacional de Astrofísica, Óptica y Electrónica INAOE
Back Work Ratio of Brayton Cycle,La relación de trabajo de retroceso de un ciclo Brayton por Malaver de la Fuente, M; Universidad Marítima del Caribe, Venezuela
Active Rectifier with Extended Functions: An Option to Voltage Sags Ride Through and Power Quality Improvement,Rectificador activo con funciones ampliadas: una alternativa para la compensación de sags de voltaje y mejorar la calidad de la red eléctrica por Núñez Gutiérrez, C A; Universidad Autónoma de San Luis Potosí, SLP,Lira Pérez, J; Universidad Autónoma de San Luis Potosí, SLP,Pazos Flores, F; Universidad Autónoma de San Luis Potosí, SLP,Echavarría Solís, R; Universidad Politécnica de Victoria, Ciudad Victoria, Tamaulipas
10