Título: Influence of Harmonics in Laboratory due to Nonlinear Loads
Autores: Chan, Risnidar; Universitas Sumatera Utara, Indonesia University Malaysia Perlis
Daut, Ismail; University Malaysia Perlis
Hasan, Syafruddin; Universitas Sumatera Utara, Indonesia University Malaysia Perlis
Hasim, Norhaidar; University Malaysia Perlis
Fecha: 2012-03-14
Publicador: International journal of power electronics and drive systems
Fuente:
Tipo: info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Tema: No aplica
Descripción: This research was focused on the customer’s side of the meter which is the effect of harmonics on a laboratory in Electrical System Engineering School at K.Wai Perlis. Harmonic currents in equipments can cause them to experience overheating and increased losses, while harmonic voltage produces magnetic fields rotating at a speed corresponding to the harmonic frequency. This also results in equipments heating, mechanical vibrations and noise, reduced efficiency, reduced life, and voltage stress on insulation of equipment windings. The loads in this research are computers, Compact Fluorescent Lamps CFLs), Air Conditions and printers,which all of the loads are harmonic significant The instrument to measure and monitoring is Fluke 435 Power Quality Analyzer. With the operation of varying nonlinear loads, the injected harmonic current magnitudes and phase angles vary in a random way. This research offers the advantage of providing the utility a wealth of information on the effects of harmonics in their equipments. This will subsequently make them aware of the causes of increased cost and reduced efficiency that may be experienced by using these equipments. This paper describes the investigation cost of harmonic effect as THD, and harmonic energy losses cost.   Keywords: harmonics, nonlinear loads, Energy losses cost, THD.
Idioma: Inglés

Artículos similares:

Simulation of a Transient Fault Controller for a Grid Connected Wind Farm with Different Types of Generators por Abdel-Mageed, Helmy Mohammed; Helwan University,Sharaf, S.M.,El_masry, S.M.,El_harony, M.; Helwan University
Unified Power Quality Conditioner for voltage sag and harmonic mitigation of nonlinear loads por Latha, Y. Kusuma; Lakireddy Balireddy College of Engineering (Autonomous),Saibabu, Ch.; University College of Engineering (Autonomous),Obulesu, Y P; Lakireddy Balireddy College of Engineering(Autonomous)
Dynamic Testing & Simulation of 4 KW (5.5 Hp) Switched Reluctance Motor using PSpice por Autee, Rajesh Murlidharrao; Marathwada Shikshan Prasarak Mandal's Deogiri Technical Campus for Engineeing & Mgt Studies, Aurangabad. Aff-Dr. B.A.M.University, Aurangabad-India.
A Novel method of Starting Induction Motor - A Comparative Study por Chakrasali, R L; SDM College of Engg.&Tech., Dharwad,Sheelavant, V.R.,Nagaraja, H.N.
10 
Regeneration of ZVS converter with Resonant inductor por Prasad, J.Sivavara,Babu, Ch.Sai,Obelesh, Y.P.